1-1hit |
Owing to the large amount of speckle noise and ill-defined edges present in echocardiographic images, computer-based boundary detection of the left ventricle has proved to be a challenging problem. In this paper, a Markovian level set method for boundary detection in long-axis echocardiographic images is proposed. It combines Markov random field (MRF) model, which makes use of local statistics with level set method that handles topological changes, to detect a continuous and smooth boundary. Experimental results show that higher accuracy can be achieved with the proposed method compared with two related MRF-based methods.