1-3hit |
Chul Ho WON Dong Hun KIM Jung Hyun LEE Ki Won YOON Sang Hyo WOO Young Ho YOON Min Kyu KIM Jin Ho CHO
To detect lung area, this paper proposes curve stopping function that is based on CT coefficient of area of lung parenchyma instead of existing edge indication function. The proposed method was compared numerically using various measures and this method can detect better lung parenchyma region than existing methods. In addition, detecting procedure of the area of lung parenchyma was visually verified in lung images.
Pil Un KIM Yunjung LEE Sanghyo WOO Chulho WON Jin Ho CHO Myoung Nam KIM
Since retina blood vessels (RBV) are a major factor in ophthalmological diagnosis, it is essential to detect RBV from a fundus image. In this letter, we proposed the detection method of RBV using a morphological analysis and support vector machine classification. The proposed RBV detection method consists of three strategies: pre-processing, features extraction and classification. In pre-processing, noises were reduced and RBV were enhanced by anisotropic diffusion filtering and illumination equalization. Features were extracted by using the image intensity and morphology of RBV. And a support vector machine (SVM) classification algorithm was used to detect RBV. The proposed RBV detection method was simulated and validated by using the DRIVE database. The averages of accuracy and TPR are 0.94 and 0.78, respectively. Moreover, by comparison, we confirmed that the proposed RBV detection method detected RBV better than the recent RBV detections methods.
Yunjung LEE Pil Un KIM Jin Ho CHO Yongmin CHANG Myoung Nam KIM
In this paper, a single-channel adaptive noise canceller (SCANC) is proposed to enhance heart sounds during auscultation. Heart sounds provide important information about the condition of the heart, but other sounds interfere with heart sounds during auscultation. The adaptive noise canceller (ANC) is widely used to reduce noises from biomedical signals, but it is not suitable for enhancing auscultatory sounds acquired by a stethoscope. While the ANC needs two inputs, a stethoscope provides only one input. Other approaches, such as ECG gating and wavelet de-noising, are rather complex and difficult to implement as real-time systems. The proposed SCANC uses a single-channel input based on Heart Sound Inherency Indicator and reference generator. The architecture is simple, so it can be easily implemented in real-time systems. It was experimentally confirmed that the proposed SCANC is efficient for heart sound enhancement and is robust against the heart rate variations.