[Author] Jun'ichi HORI(3hit)

1-3hit
  • Electrocardiogram Data Compression by the Oslo Algorithm and DP Matching

    Yoshiaki SAITOH  Yasushi HASEGAWA  Tohru KIRYU  Jun'ichi HORI  

     
    PAPER

      Vol:
    E76-D No:12
      Page(s):
    1411-1418

    We use the B spline function and apply the Oslo algorithm to minimize the number of control points in electrocardiogram (ECG) waveform compression under the limitation of evaluation indexes. This method is based on dynamic programming matching to transfer the control points of a reference ECG waveform to the succeeding ECG waveforms. This reduces the execution time for beat-to-beat processing. We also reduced the processing time at several compression stages. When the difference percent normalized root mean square difference is around 10, our method gives the highest compression ratio at a sampling frequency of 250 Hz.

  • Implantable Temperature Measurement System Using the Parametron Phenomenon

    Yoshiaki SAITOH  Akira KANKE  Isamu SHINOZAKI  Tohru KIRYU  Jun'ichi HORI  

     
    PAPER-Measurement and Metrology

      Vol:
    E79-B No:8
      Page(s):
    1129-1134

    Adapting the principle of parametron oscillation, a small implantable temperature sensor requiring no internal power supply is described. Since this sensor's oscillation frequency is half that of the excitation frequency, the oscillated signal can be measured from the reception side, free of any signal, interference, simply by positioning the sensor and the excitation antenna so that; 1) they are separated up to 95 cm in the air; 2) a 41 cm gap, the phantom equivalent of the thickness of the human abdomen maintain between them. In the temperature-dependent quartz resonator sensor, oscillation occurs only when frequency and temperature correspond. The excitation power is then adjusted so that the frequency bandwidth narrows. As a result, the margin of error in measuring the temperature is minimized; (0.07).

  • Improvement of the Time-Domain Response of a Thermodilution Sensor by the Natural Observation System

    Jun'ichi HORI  Yoshiaki SAITOH  Tohru KIRYU  

     
    PAPER

      Vol:
    E77-A No:5
      Page(s):
    784-791

    When measuring the ejection fraction for the evaluation of the ventricular pumping function by means of the thermodilution technique, the slow response a conventional thermistor has caused it to be considered unsuitable, and fast thermistors have been proposed as an alternative. However, in this paper we propose improving the time-domain response of a conventional thermistor using a signal processing technique composed of a series of first-order high-pass filters which is known as the natural observation system. We considered the rise time of the thermistor in response to a step temperature change to effect correction for the measurement of the ejection fraction. The coefficients of the natural observation system were calculated by minimizing the square error between the step-response signal of the thermistor and the band-limited reference signal. In an experiment using a model ventricle, the thermodilution curve obtained from a conventional thermistor was improved using the proposed technique, thus enabling successful measurement of the ejection fraction of the ventricles.