The search functionality is under construction.
The search functionality is under construction.

Keyword Search Result

[Keyword] acceleration factor(1hit)

1-1hit
  • Acceleration Factor for Tarnish Testing of Silver Contact Surface

    Terutaka TAMAI  Yasuhiro KURANAGA  

     
    PAPER-Electronic Circuits

      Vol:
    E78-C No:9
      Page(s):
    1273-1278

    Silver is a fundamental material for electrical contact application. In spite of high electrical conductivity and economical advantage, silver surface is corroded easily by environment contained sulfide. A corrosion product as Ag2S deteriorates the property of contact reliability. In order to examine contact reliability, the acceleration tests have been accepted widely in industries. In the present study, the acceleration factor of the contact reliability for the sulfide film on the surface of silver contact which was subject to the tarnish acceleration test was clarified in comparison with the film grown in a normal office environment. The accelerated environment based on the Japan Electric Industry Development Association (JEIDA) standard No.25 was adopted. This environment is consisted of air contained 3 ppm H2S gas under 40, 85-95% RH. The growth rate of the sulfide film (Ag2S) was evaluated by applying the ellipsometry analysis. In the results, it was found that growth of Ag2S film of 500 in thickness in the normal office environment required corrosion time of 3103 h. This thickness of 500 caused increase in contact resistance of 0.1-1.0 (Ω). However, in the accelerated environment, corrosion time decreased to 1.7 h for same thickness. Therefore, the acceleration factor was obtained by comparison of these time as 1.8103 for the standard test of JEIDA.