The search functionality is under construction.
The search functionality is under construction.

Keyword Search Result

[Keyword] attenuation measurement(1hit)

1-1hit
  • Double Step Technique for Accurate Microwave High Attenuation Measurements Open Access

    Anton WIDARTA  

     
    PAPER

      Pubricized:
    2024/06/11
      Vol:
    E107-C No:10
      Page(s):
    349-354

    A double step attenuation measurement technique using a non-isolating gauge block attenuator (GBA) has been proposed for accurate measurements of radio frequency and microwave high attenuation. For fixed attenuator as a device under test (DUT), a medium value (≤ 60 dB) attenuator is used as the GBA which connected directly between the test ports, then high attenuation of the DUT is measured in two setups as follows. 1) Thru and GBA with normal power level and 2) GBA and DUT with higher power level. This approach removes the need to isolate the GBA, therefore, accurate measurements of high attenuation can be obtained simply over a broad frequency range. For variable or step attenuator as a DUT, one of the attenuation sections of the DUT is applied as the GBA. Detailed analyses and those verification measurements are carried out both for fixed attenuator, as well as for variable attenuator and show good agreement.