1-1hit |
Shogo SEMBA Hiroshi SAITO Masato TATSUOKA Katsuya FUJIMURA
In this paper, we propose four optimization methods during the Register Transfer Level (RTL) conversion from synchronous RTL models into asynchronous RTL models. The modularization of data-path resources and the use of appropriate D flip-flops reduce the circuit area. Fixing the control signal of the multiplexers and inserting latches for the data-path resources reduce the dynamic power consumption. In the experiment, we evaluated the effect of the proposed optimization methods. The combination of all optimization methods could reduce the energy consumption by 21.9% on average compared to the ones without the proposed optimization methods.