The search functionality is under construction.

Keyword Search Result

[Keyword] peak detection(3hit)

1-3hit
  • Measurement of Length of a Single Tooth Using PCA-Signature and Bezier Curve

    Pramual CHOORAT  Werapon CHIRACHARIT  Kosin CHAMNONGTHAI  Takao ONOYE  

     
    PAPER

      Vol:
    E97-A No:11
      Page(s):
    2161-2169

    In developing an automatic system of a single tooth length measurement on x-ray image, since a tooth shape is assumed to be straight and curve, an algorithm which can accurately deal with straight and curve is required. This paper proposes an automatic algorithm for measuring the length of single straight and curve teeth. In the algorithm consisting of control point determination, curve fitting, and length measurement, PCA is employed to find the first and second principle axes as vertical and horizontal ones of the tooth, and two terminal points of vertical axis and the junction of those axes are determined as three first-order control points. Signature is then used to find a peak representing tooth root apex as the forth control point. Bezier curve, Euclidean distance, and perspective transform are finally applied with determined four control points in curve fitting and tooth length measurement. In the experiment, comparing with the conventional PCA-based method, the average mean square error (MSE) of the line points plotted by the expert is reduced from 7.548 pixels to 4.714 pixels for tooth image type-I, whereas the average MSE value is reduced from 7.713 pixels and 7.877 pixels to 4.809 pixels and 5.253 pixels for left side and right side of tooth image type-H, respectively.

  • A Single Tooth Segmentation Using PCA-Stacked Gabor Filter and Active Contour

    Pramual CHOORAT  Werapon CHIRACHARIT  Kosin CHAMNONGTHAI  Takao ONOYE  

     
    PAPER-Image Processing

      Vol:
    E96-A No:11
      Page(s):
    2169-2178

    In tooth contour extraction there is insufficient intensity difference in x-ray images between the tooth and dental bone. This difference must be enhanced in order to improve the accuracy of tooth segmentation. This paper proposes a method to improve the intensity between the tooth and dental bone. This method consists of an estimation of tooth orientation (intensity projection, smoothing filter, and peak detection) and PCA-Stacked Gabor with ellipse Gabor banks. Tooth orientation estimation is performed to determine the angle of a single oriented tooth. PCA-Stacked Gabor with ellipse Gabor banks is then used, in particular to enhance the border between the tooth and dental bone. Finally, active contour extraction is performed in order to determine tooth contour. In the experiment, in comparison with the conventional active contour without edge (ACWE) method, the average mean square error (MSE) values of extracted tooth contour points are reduced from 26.93% and 16.02% to 19.07% and 13.42% for tooth x-ray type I and type H images, respectively.

  • Robust Physical Layer Signaling Transmission over OFDM Systems

    Lifeng HE  Fang YANG  Zhaocheng WANG  

     
    LETTER-Wireless Communication Technologies

      Vol:
    E94-B No:10
      Page(s):
    2900-2902

    In this letter, a novel physical layer signaling transmission scheme is proposed, where the signaling information is conveyed by a pair of training sequences located in the odd and even subcarriers of an orthogonal frequency division multiplexing (OFDM) training symbol. At the receiver side, only a single correlator is required to detect the signaling information. Computer simulations verify the proposed signaling could outperform the S1 signaling and achieve similar robustness as the S2 signaling of the DVB-T2 standard.