The search functionality is under construction.
The search functionality is under construction.

Keyword Search Result

[Keyword] screen coordinates calibration(1hit)

1-1hit
  • A Shadow Cursor for Calibrating Screen Coordinates of Tabletop Displays and Its Evaluation

    Makio ISHIHARA  Yukio ISHIHARA  

     
    PAPER-Human-computer Interaction

      Pubricized:
    2017/03/16
      Vol:
    E100-D No:6
      Page(s):
    1271-1279

    This paper discusses the use of a common computer mouse as a pointing interface for tabletop displays. In the use of a common computer mouse for tabletop displays, there might be an angular distance between the screen coordinates and the mouse control coordinates. To align those coordinates, this paper introduces a screen coordinates calibration technique using a shadow cursor. A shadow cursor is the basic idea of manipulating a mouse cursor without any visual feedbacks. The shadow cursor plays an important role in obtaining the angular distance between the two coordinates. It enables the user to perform a simple mouse manipulation so that screen coordinates calibration will be completed in less than a second.