The search functionality is under construction.

Keyword Search Result

[Keyword] second order constant K band-pass filter(1hit)

1-1hit
  • Design of Class DE Inverter with Second Order Constant K Band-Pass Filter

    Motoki KATAYAMA  Hiroyuki HASE  Hiroo SEKIYA  Jianming LU  Takashi YAHAGI  

     
    PAPER-Nonlinear Circuits

      Vol:
    E90-A No:10
      Page(s):
    2132-2140

    In this paper, class DE inverter with second order constant K band-pass filter is proposed. In the proposed inverter, the band-pass filter is used instead of the resonant filter in class DE inverter presented at the previous papers. By using band-pass filter, two important results can be gotten. One is the sensitivity of the output voltage to the operating frequency is suppressed by using band-pass filter. The other is that zero voltage switching operation appears when the operating frequency is lower than the nominal frequency. Moreover, it keeps the advantage of class DE inverter with resonant filter, that is, high power conversion efficiency under high frequency operation because of class E switching. The laboratory experiments achieve 90.4% power conversion efficiency under 1.98 W output power and 1.0 MHz operation.