This paper proposes a technique for broadcasting control of Smart Air Conditioners (SACs) by implementing the Narrowband Powerline Communications (NB-PLC) technology. The Master Control Room (MCR) generates commands for SACs operation that are sent over power lines by using the communication protocol known as Smart Energy Profile 1.0 (SEP 1.0). The proposed system can also offers features like Demand Response (DR) to facilitate the Smart Grid (SG). Field measurements elucidate the performance of NB-PLC systems. Measurements are carried out by injecting and receiving the NB-PLC signal over low voltage (LV) power lines, medium voltage (MV) power lines and across transformers. A hybrid communication system, NB-PLC integrated with Optical Fiber Network (OFN), is developed for the automation of Distribution System (DS) of Lahore Electric Supply Company (LESCO). The developed system was tested for the DR program in order to support the Smart Air Conditioning system within Lahore. It is suggested that by adjusting the commercial SACs parameters, the task of energy conservation can be achieved by optimizing the peak load curves for greater efficiency. Moreover, data of various types of appliances can also be communicated to the MCR for the purpose of demand side management.
Bilal MASOOD
University Campus
Waheed Aftab KHAN
University Campus
Manzoor ELLAHI
University Campus
Talha ARSHAD
University Campus
Muhammad Farooq AMJAD
University Campus
Arslan TAHIR
University Campus
Muhammad USMAN
The University of Lahore
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Bilal MASOOD, Waheed Aftab KHAN, Manzoor ELLAHI, Talha ARSHAD, Muhammad Farooq AMJAD, Arslan TAHIR, Muhammad USMAN, "Demand Response Control Technique for Smart Air Conditioners Using NB-PLC" in IEICE TRANSACTIONS on Communications,
vol. E101-B, no. 3, pp. 723-730, March 2018, doi: 10.1587/transcom.2017EBP3105.
Abstract: This paper proposes a technique for broadcasting control of Smart Air Conditioners (SACs) by implementing the Narrowband Powerline Communications (NB-PLC) technology. The Master Control Room (MCR) generates commands for SACs operation that are sent over power lines by using the communication protocol known as Smart Energy Profile 1.0 (SEP 1.0). The proposed system can also offers features like Demand Response (DR) to facilitate the Smart Grid (SG). Field measurements elucidate the performance of NB-PLC systems. Measurements are carried out by injecting and receiving the NB-PLC signal over low voltage (LV) power lines, medium voltage (MV) power lines and across transformers. A hybrid communication system, NB-PLC integrated with Optical Fiber Network (OFN), is developed for the automation of Distribution System (DS) of Lahore Electric Supply Company (LESCO). The developed system was tested for the DR program in order to support the Smart Air Conditioning system within Lahore. It is suggested that by adjusting the commercial SACs parameters, the task of energy conservation can be achieved by optimizing the peak load curves for greater efficiency. Moreover, data of various types of appliances can also be communicated to the MCR for the purpose of demand side management.
URL: https://global.ieice.org/en_transactions/communications/10.1587/transcom.2017EBP3105/_p
Copy
@ARTICLE{e101-b_3_723,
author={Bilal MASOOD, Waheed Aftab KHAN, Manzoor ELLAHI, Talha ARSHAD, Muhammad Farooq AMJAD, Arslan TAHIR, Muhammad USMAN, },
journal={IEICE TRANSACTIONS on Communications},
title={Demand Response Control Technique for Smart Air Conditioners Using NB-PLC},
year={2018},
volume={E101-B},
number={3},
pages={723-730},
abstract={This paper proposes a technique for broadcasting control of Smart Air Conditioners (SACs) by implementing the Narrowband Powerline Communications (NB-PLC) technology. The Master Control Room (MCR) generates commands for SACs operation that are sent over power lines by using the communication protocol known as Smart Energy Profile 1.0 (SEP 1.0). The proposed system can also offers features like Demand Response (DR) to facilitate the Smart Grid (SG). Field measurements elucidate the performance of NB-PLC systems. Measurements are carried out by injecting and receiving the NB-PLC signal over low voltage (LV) power lines, medium voltage (MV) power lines and across transformers. A hybrid communication system, NB-PLC integrated with Optical Fiber Network (OFN), is developed for the automation of Distribution System (DS) of Lahore Electric Supply Company (LESCO). The developed system was tested for the DR program in order to support the Smart Air Conditioning system within Lahore. It is suggested that by adjusting the commercial SACs parameters, the task of energy conservation can be achieved by optimizing the peak load curves for greater efficiency. Moreover, data of various types of appliances can also be communicated to the MCR for the purpose of demand side management.},
keywords={},
doi={10.1587/transcom.2017EBP3105},
ISSN={1745-1345},
month={March},}
Copy
TY - JOUR
TI - Demand Response Control Technique for Smart Air Conditioners Using NB-PLC
T2 - IEICE TRANSACTIONS on Communications
SP - 723
EP - 730
AU - Bilal MASOOD
AU - Waheed Aftab KHAN
AU - Manzoor ELLAHI
AU - Talha ARSHAD
AU - Muhammad Farooq AMJAD
AU - Arslan TAHIR
AU - Muhammad USMAN
PY - 2018
DO - 10.1587/transcom.2017EBP3105
JO - IEICE TRANSACTIONS on Communications
SN - 1745-1345
VL - E101-B
IS - 3
JA - IEICE TRANSACTIONS on Communications
Y1 - March 2018
AB - This paper proposes a technique for broadcasting control of Smart Air Conditioners (SACs) by implementing the Narrowband Powerline Communications (NB-PLC) technology. The Master Control Room (MCR) generates commands for SACs operation that are sent over power lines by using the communication protocol known as Smart Energy Profile 1.0 (SEP 1.0). The proposed system can also offers features like Demand Response (DR) to facilitate the Smart Grid (SG). Field measurements elucidate the performance of NB-PLC systems. Measurements are carried out by injecting and receiving the NB-PLC signal over low voltage (LV) power lines, medium voltage (MV) power lines and across transformers. A hybrid communication system, NB-PLC integrated with Optical Fiber Network (OFN), is developed for the automation of Distribution System (DS) of Lahore Electric Supply Company (LESCO). The developed system was tested for the DR program in order to support the Smart Air Conditioning system within Lahore. It is suggested that by adjusting the commercial SACs parameters, the task of energy conservation can be achieved by optimizing the peak load curves for greater efficiency. Moreover, data of various types of appliances can also be communicated to the MCR for the purpose of demand side management.
ER -