Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. The magnetic saturation is observed in onboard isolated bridge-type DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Based on the analysis a solution for the magnetic saturation is proposed. The effectiveness of proposed method is also confirmed by experiments.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Teruhiko KOHAMA, Sunao TOKIMATSU, Akio INOUE, "Magnetic Saturation Due to Fast Dynamic Response and Its Eliminating Method in Bridge-Type DC-DC Converter" in IEICE TRANSACTIONS on Communications,
vol. E93-B, no. 8, pp. 2165-2170, August 2010, doi: 10.1587/transcom.E93.B.2165.
Abstract: Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. The magnetic saturation is observed in onboard isolated bridge-type DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Based on the analysis a solution for the magnetic saturation is proposed. The effectiveness of proposed method is also confirmed by experiments.
URL: https://global.ieice.org/en_transactions/communications/10.1587/transcom.E93.B.2165/_p
Copy
@ARTICLE{e93-b_8_2165,
author={Teruhiko KOHAMA, Sunao TOKIMATSU, Akio INOUE, },
journal={IEICE TRANSACTIONS on Communications},
title={Magnetic Saturation Due to Fast Dynamic Response and Its Eliminating Method in Bridge-Type DC-DC Converter},
year={2010},
volume={E93-B},
number={8},
pages={2165-2170},
abstract={Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. The magnetic saturation is observed in onboard isolated bridge-type DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Based on the analysis a solution for the magnetic saturation is proposed. The effectiveness of proposed method is also confirmed by experiments.},
keywords={},
doi={10.1587/transcom.E93.B.2165},
ISSN={1745-1345},
month={August},}
Copy
TY - JOUR
TI - Magnetic Saturation Due to Fast Dynamic Response and Its Eliminating Method in Bridge-Type DC-DC Converter
T2 - IEICE TRANSACTIONS on Communications
SP - 2165
EP - 2170
AU - Teruhiko KOHAMA
AU - Sunao TOKIMATSU
AU - Akio INOUE
PY - 2010
DO - 10.1587/transcom.E93.B.2165
JO - IEICE TRANSACTIONS on Communications
SN - 1745-1345
VL - E93-B
IS - 8
JA - IEICE TRANSACTIONS on Communications
Y1 - August 2010
AB - Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. The magnetic saturation is observed in onboard isolated bridge-type DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Based on the analysis a solution for the magnetic saturation is proposed. The effectiveness of proposed method is also confirmed by experiments.
ER -