A mode transformer between the NRD guide and the vertical strip line was developed and applied to the right angle corner, T-junction, and 3-port junction at 60 GHz. Emphasis was placed on a fully CAD-based design procedure by using an electromagnetic field simulator. Agreement between the simulated and measured performances of the junction circuit was obtained, and thus the validity of the design procedure was confirmed. A well-balanced transmission coefficient of the 3-port junction, found to be 4
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Futoshi KUROKI, Makoto KIMURA, Tsukasa YONEYAMA, "Fully CAD-Based Design of a Mode Transformer between NRD Guide and Vertical Strip Line and Its Applications to Junction Circuits at 60 GHz" in IEICE TRANSACTIONS on Electronics,
vol. E88-C, no. 1, pp. 105-109, January 2005, doi: 10.1093/ietele/e88-c.1.105.
Abstract: A mode transformer between the NRD guide and the vertical strip line was developed and applied to the right angle corner, T-junction, and 3-port junction at 60 GHz. Emphasis was placed on a fully CAD-based design procedure by using an electromagnetic field simulator. Agreement between the simulated and measured performances of the junction circuit was obtained, and thus the validity of the design procedure was confirmed. A well-balanced transmission coefficient of the 3-port junction, found to be 4
URL: https://global.ieice.org/en_transactions/electronics/10.1093/ietele/e88-c.1.105/_p
Copy
@ARTICLE{e88-c_1_105,
author={Futoshi KUROKI, Makoto KIMURA, Tsukasa YONEYAMA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Fully CAD-Based Design of a Mode Transformer between NRD Guide and Vertical Strip Line and Its Applications to Junction Circuits at 60 GHz},
year={2005},
volume={E88-C},
number={1},
pages={105-109},
abstract={A mode transformer between the NRD guide and the vertical strip line was developed and applied to the right angle corner, T-junction, and 3-port junction at 60 GHz. Emphasis was placed on a fully CAD-based design procedure by using an electromagnetic field simulator. Agreement between the simulated and measured performances of the junction circuit was obtained, and thus the validity of the design procedure was confirmed. A well-balanced transmission coefficient of the 3-port junction, found to be 4
keywords={},
doi={10.1093/ietele/e88-c.1.105},
ISSN={},
month={January},}
Copy
TY - JOUR
TI - Fully CAD-Based Design of a Mode Transformer between NRD Guide and Vertical Strip Line and Its Applications to Junction Circuits at 60 GHz
T2 - IEICE TRANSACTIONS on Electronics
SP - 105
EP - 109
AU - Futoshi KUROKI
AU - Makoto KIMURA
AU - Tsukasa YONEYAMA
PY - 2005
DO - 10.1093/ietele/e88-c.1.105
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E88-C
IS - 1
JA - IEICE TRANSACTIONS on Electronics
Y1 - January 2005
AB - A mode transformer between the NRD guide and the vertical strip line was developed and applied to the right angle corner, T-junction, and 3-port junction at 60 GHz. Emphasis was placed on a fully CAD-based design procedure by using an electromagnetic field simulator. Agreement between the simulated and measured performances of the junction circuit was obtained, and thus the validity of the design procedure was confirmed. A well-balanced transmission coefficient of the 3-port junction, found to be 4
ER -