Measurement of Minimum Arc Current of Ag Contacts in DC Resistive and Inductive Load Conditions

Makoto HASEGAWA, Yusuke KAMADA

  • Full Text Views

    0

  • Cite this

Summary :

Arc occurrence rates were measured for Ag contacts in DC resistive and inductive load circuits. In inductive load conditions, arc occurrence rates in general came close to 100% at around 0.4 A, the conventional minimum arc current level of Ag. In resistive load conditions, the similar results were obtained with 30 V, while arc occurrence rates close to 50% were still obtained at around 0.4 A with 14 V and 10 V. Careful attention should be paid to the term "minimum arc current" to avoid misinterpretation thereof.

Publication
IEICE TRANSACTIONS on Electronics Vol.E89-C No.8 pp.1160-1163
Publication Date
2006/08/01
Publicized
Online ISSN
1745-1353
DOI
10.1093/ietele/e89-c.8.1160
Type of Manuscript
Special Section LETTER (Special Section on Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
Category
Arc Discharge & Related Phenomena