Arc occurrence rates were measured for Ag contacts in DC resistive and inductive load circuits. In inductive load conditions, arc occurrence rates in general came close to 100% at around 0.4 A, the conventional minimum arc current level of Ag. In resistive load conditions, the similar results were obtained with 30 V, while arc occurrence rates close to 50% were still obtained at around 0.4 A with 14 V and 10 V. Careful attention should be paid to the term "minimum arc current" to avoid misinterpretation thereof.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Makoto HASEGAWA, Yusuke KAMADA, "Measurement of Minimum Arc Current of Ag Contacts in DC Resistive and Inductive Load Conditions" in IEICE TRANSACTIONS on Electronics,
vol. E89-C, no. 8, pp. 1160-1163, August 2006, doi: 10.1093/ietele/e89-c.8.1160.
Abstract: Arc occurrence rates were measured for Ag contacts in DC resistive and inductive load circuits. In inductive load conditions, arc occurrence rates in general came close to 100% at around 0.4 A, the conventional minimum arc current level of Ag. In resistive load conditions, the similar results were obtained with 30 V, while arc occurrence rates close to 50% were still obtained at around 0.4 A with 14 V and 10 V. Careful attention should be paid to the term "minimum arc current" to avoid misinterpretation thereof.
URL: https://global.ieice.org/en_transactions/electronics/10.1093/ietele/e89-c.8.1160/_p
Copy
@ARTICLE{e89-c_8_1160,
author={Makoto HASEGAWA, Yusuke KAMADA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Measurement of Minimum Arc Current of Ag Contacts in DC Resistive and Inductive Load Conditions},
year={2006},
volume={E89-C},
number={8},
pages={1160-1163},
abstract={Arc occurrence rates were measured for Ag contacts in DC resistive and inductive load circuits. In inductive load conditions, arc occurrence rates in general came close to 100% at around 0.4 A, the conventional minimum arc current level of Ag. In resistive load conditions, the similar results were obtained with 30 V, while arc occurrence rates close to 50% were still obtained at around 0.4 A with 14 V and 10 V. Careful attention should be paid to the term "minimum arc current" to avoid misinterpretation thereof.},
keywords={},
doi={10.1093/ietele/e89-c.8.1160},
ISSN={1745-1353},
month={August},}
Copy
TY - JOUR
TI - Measurement of Minimum Arc Current of Ag Contacts in DC Resistive and Inductive Load Conditions
T2 - IEICE TRANSACTIONS on Electronics
SP - 1160
EP - 1163
AU - Makoto HASEGAWA
AU - Yusuke KAMADA
PY - 2006
DO - 10.1093/ietele/e89-c.8.1160
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E89-C
IS - 8
JA - IEICE TRANSACTIONS on Electronics
Y1 - August 2006
AB - Arc occurrence rates were measured for Ag contacts in DC resistive and inductive load circuits. In inductive load conditions, arc occurrence rates in general came close to 100% at around 0.4 A, the conventional minimum arc current level of Ag. In resistive load conditions, the similar results were obtained with 30 V, while arc occurrence rates close to 50% were still obtained at around 0.4 A with 14 V and 10 V. Careful attention should be paid to the term "minimum arc current" to avoid misinterpretation thereof.
ER -