To improve the resolution of the color CRTs, we propose a new electrostatic lens system which has two additional electrodes between the focus electrode and the anode electrode. The anode voltage and focus voltage are supplied on these additional electrodes. The numerical simulation shows that the system can reduce the third order aberration coefficients almost up to 31% of the conventional system. And the experiments show that the typical beam spot diameter is improved by nearly 20% of the conventional system.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Katsumi OONO, Shuhei NAKATA, Soichiro OKUDA, "Simulation Designing and Experiment of Low Aberration Lens Systems for Color Display Tubes" in IEICE TRANSACTIONS on Electronics,
vol. E81-C, no. 11, pp. 1711-1714, November 1998, doi: .
Abstract: To improve the resolution of the color CRTs, we propose a new electrostatic lens system which has two additional electrodes between the focus electrode and the anode electrode. The anode voltage and focus voltage are supplied on these additional electrodes. The numerical simulation shows that the system can reduce the third order aberration coefficients almost up to 31% of the conventional system. And the experiments show that the typical beam spot diameter is improved by nearly 20% of the conventional system.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e81-c_11_1711/_p
Copy
@ARTICLE{e81-c_11_1711,
author={Katsumi OONO, Shuhei NAKATA, Soichiro OKUDA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Simulation Designing and Experiment of Low Aberration Lens Systems for Color Display Tubes},
year={1998},
volume={E81-C},
number={11},
pages={1711-1714},
abstract={To improve the resolution of the color CRTs, we propose a new electrostatic lens system which has two additional electrodes between the focus electrode and the anode electrode. The anode voltage and focus voltage are supplied on these additional electrodes. The numerical simulation shows that the system can reduce the third order aberration coefficients almost up to 31% of the conventional system. And the experiments show that the typical beam spot diameter is improved by nearly 20% of the conventional system.},
keywords={},
doi={},
ISSN={},
month={November},}
Copy
TY - JOUR
TI - Simulation Designing and Experiment of Low Aberration Lens Systems for Color Display Tubes
T2 - IEICE TRANSACTIONS on Electronics
SP - 1711
EP - 1714
AU - Katsumi OONO
AU - Shuhei NAKATA
AU - Soichiro OKUDA
PY - 1998
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E81-C
IS - 11
JA - IEICE TRANSACTIONS on Electronics
Y1 - November 1998
AB - To improve the resolution of the color CRTs, we propose a new electrostatic lens system which has two additional electrodes between the focus electrode and the anode electrode. The anode voltage and focus voltage are supplied on these additional electrodes. The numerical simulation shows that the system can reduce the third order aberration coefficients almost up to 31% of the conventional system. And the experiments show that the typical beam spot diameter is improved by nearly 20% of the conventional system.
ER -