Corrosion Mechanism Analysis of Salt Spray Test and Sulfur Dioxide Test on Gold Plated Connector Contact

Tadashi SHINTANI

  • Full Text Views

    0

  • Cite this

Summary :

Gold on connector contacts is superior in environmental resistance. However, pores existing gold film are source to trigger the corrosion reaction between gold and base metal. For examination of the contacts, it has been popular to apply "Salt Spray Test" and "Sulfur Dioxide Test. " There are some differences of the corrosion products between two tests. Main metal forming the product in Salt Spray is Copper, and main metal in Sulfur Dioxide is Nickel. To investigate the reason, we tried to employ an electro-chemical method. As a result, it was found that there was the difference between the respective galvanic cell combinations generated through pores.