This paper proposed the method as an estimation on the size of discharge spots through observation on traces after the discharge arose in circumstances gases mixed hydrocarbon gas. Namely, the circular carbonaceous deposit and the carbonaceous heap are observed on cathode and anode surface, respectively, after the short gap discharge arises in N2+NO+CH4 gases. The current density, which is the normal conversion current density, is calculated from the size of the trace of discharge and its value is about 1.0
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Kagehiro ITOYAMA, Takeshi YANOBE, "Estimation for the Spot Size of Short Gap Discharge in Near One Atmospheric Pressure" in IEICE TRANSACTIONS on Electronics,
vol. E82-C, no. 1, pp. 55-59, January 1999, doi: .
Abstract: This paper proposed the method as an estimation on the size of discharge spots through observation on traces after the discharge arose in circumstances gases mixed hydrocarbon gas. Namely, the circular carbonaceous deposit and the carbonaceous heap are observed on cathode and anode surface, respectively, after the short gap discharge arises in N2+NO+CH4 gases. The current density, which is the normal conversion current density, is calculated from the size of the trace of discharge and its value is about 1.0
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e82-c_1_55/_p
Copy
@ARTICLE{e82-c_1_55,
author={Kagehiro ITOYAMA, Takeshi YANOBE, },
journal={IEICE TRANSACTIONS on Electronics},
title={Estimation for the Spot Size of Short Gap Discharge in Near One Atmospheric Pressure},
year={1999},
volume={E82-C},
number={1},
pages={55-59},
abstract={This paper proposed the method as an estimation on the size of discharge spots through observation on traces after the discharge arose in circumstances gases mixed hydrocarbon gas. Namely, the circular carbonaceous deposit and the carbonaceous heap are observed on cathode and anode surface, respectively, after the short gap discharge arises in N2+NO+CH4 gases. The current density, which is the normal conversion current density, is calculated from the size of the trace of discharge and its value is about 1.0
keywords={},
doi={},
ISSN={},
month={January},}
Copy
TY - JOUR
TI - Estimation for the Spot Size of Short Gap Discharge in Near One Atmospheric Pressure
T2 - IEICE TRANSACTIONS on Electronics
SP - 55
EP - 59
AU - Kagehiro ITOYAMA
AU - Takeshi YANOBE
PY - 1999
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E82-C
IS - 1
JA - IEICE TRANSACTIONS on Electronics
Y1 - January 1999
AB - This paper proposed the method as an estimation on the size of discharge spots through observation on traces after the discharge arose in circumstances gases mixed hydrocarbon gas. Namely, the circular carbonaceous deposit and the carbonaceous heap are observed on cathode and anode surface, respectively, after the short gap discharge arises in N2+NO+CH4 gases. The current density, which is the normal conversion current density, is calculated from the size of the trace of discharge and its value is about 1.0
ER -