This study is intended to realize an in-situ gas sensor based upon the principle of millimeter/submillimeter wave spectroscopy. In-situ gas sensor will be attractive because of gas selectivity, multiple parametric measurement such as gas temperature, pressure and density, and of the in-situ measurement capability. One of the major technical problem to be solved is to develop an instrument accurate enough to discern the spectrum change due to the variation of parameters such as temperature. In this paper a proposed gas absorption measurement system is investigated, which schematically consists of Fabry-Perot type gas cell for effective long path length, and vector signal processing to reject leak signal coupled between resonator input and output ports so as to achieve precise absorption measurement. Also included is an parametric study of oxygen absorption characteristics, which is served as the predicted value in the evaluation of the instrument. The experiment at 60 GHz and 120 GHz bands using oxygen demonstrates the effectiveness of the current system configuration.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Toshitatsu SUZUKI, Hidenori SASANUMA, Masashi SANO, Kenichi SHIODA, Yasuo WATANABE, "Vector Signal Processing for 60-120 GHz Gas Absorption Measurement" in IEICE TRANSACTIONS on Electronics,
vol. E84-C, no. 12, pp. 1900-1904, December 2001, doi: .
Abstract: This study is intended to realize an in-situ gas sensor based upon the principle of millimeter/submillimeter wave spectroscopy. In-situ gas sensor will be attractive because of gas selectivity, multiple parametric measurement such as gas temperature, pressure and density, and of the in-situ measurement capability. One of the major technical problem to be solved is to develop an instrument accurate enough to discern the spectrum change due to the variation of parameters such as temperature. In this paper a proposed gas absorption measurement system is investigated, which schematically consists of Fabry-Perot type gas cell for effective long path length, and vector signal processing to reject leak signal coupled between resonator input and output ports so as to achieve precise absorption measurement. Also included is an parametric study of oxygen absorption characteristics, which is served as the predicted value in the evaluation of the instrument. The experiment at 60 GHz and 120 GHz bands using oxygen demonstrates the effectiveness of the current system configuration.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e84-c_12_1900/_p
Copy
@ARTICLE{e84-c_12_1900,
author={Toshitatsu SUZUKI, Hidenori SASANUMA, Masashi SANO, Kenichi SHIODA, Yasuo WATANABE, },
journal={IEICE TRANSACTIONS on Electronics},
title={Vector Signal Processing for 60-120 GHz Gas Absorption Measurement},
year={2001},
volume={E84-C},
number={12},
pages={1900-1904},
abstract={This study is intended to realize an in-situ gas sensor based upon the principle of millimeter/submillimeter wave spectroscopy. In-situ gas sensor will be attractive because of gas selectivity, multiple parametric measurement such as gas temperature, pressure and density, and of the in-situ measurement capability. One of the major technical problem to be solved is to develop an instrument accurate enough to discern the spectrum change due to the variation of parameters such as temperature. In this paper a proposed gas absorption measurement system is investigated, which schematically consists of Fabry-Perot type gas cell for effective long path length, and vector signal processing to reject leak signal coupled between resonator input and output ports so as to achieve precise absorption measurement. Also included is an parametric study of oxygen absorption characteristics, which is served as the predicted value in the evaluation of the instrument. The experiment at 60 GHz and 120 GHz bands using oxygen demonstrates the effectiveness of the current system configuration.},
keywords={},
doi={},
ISSN={},
month={December},}
Copy
TY - JOUR
TI - Vector Signal Processing for 60-120 GHz Gas Absorption Measurement
T2 - IEICE TRANSACTIONS on Electronics
SP - 1900
EP - 1904
AU - Toshitatsu SUZUKI
AU - Hidenori SASANUMA
AU - Masashi SANO
AU - Kenichi SHIODA
AU - Yasuo WATANABE
PY - 2001
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E84-C
IS - 12
JA - IEICE TRANSACTIONS on Electronics
Y1 - December 2001
AB - This study is intended to realize an in-situ gas sensor based upon the principle of millimeter/submillimeter wave spectroscopy. In-situ gas sensor will be attractive because of gas selectivity, multiple parametric measurement such as gas temperature, pressure and density, and of the in-situ measurement capability. One of the major technical problem to be solved is to develop an instrument accurate enough to discern the spectrum change due to the variation of parameters such as temperature. In this paper a proposed gas absorption measurement system is investigated, which schematically consists of Fabry-Perot type gas cell for effective long path length, and vector signal processing to reject leak signal coupled between resonator input and output ports so as to achieve precise absorption measurement. Also included is an parametric study of oxygen absorption characteristics, which is served as the predicted value in the evaluation of the instrument. The experiment at 60 GHz and 120 GHz bands using oxygen demonstrates the effectiveness of the current system configuration.