Effects of the sample insertion holes of the TM010 mode cylindrical cavity are analyzed on the basis of rigorous analysis by the Ritz-Galerkin method. The measurement accuracy of complex permittivity is examined by comparing the values by the perturbation method with ones by the rigorous analysis. Charts of relative errors Δ ε/εp and Δ tan δ/tan δp are presented, which are useful to measure the complex permittivity accurately by the perturbation method. The present analysis extends the validity of the conventional perturbation method.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Hirokazu KAWABATA, Hiroshi TANPO, Yoshio KOBAYASHI, "An Improvement of the Perturbation Method Using a TM010 Mode Cylindrical Cavity" in IEICE TRANSACTIONS on Electronics,
vol. E86-C, no. 12, pp. 2371-2378, December 2003, doi: .
Abstract: Effects of the sample insertion holes of the TM010 mode cylindrical cavity are analyzed on the basis of rigorous analysis by the Ritz-Galerkin method. The measurement accuracy of complex permittivity is examined by comparing the values by the perturbation method with ones by the rigorous analysis. Charts of relative errors Δ ε/εp and Δ tan δ/tan δp are presented, which are useful to measure the complex permittivity accurately by the perturbation method. The present analysis extends the validity of the conventional perturbation method.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e86-c_12_2371/_p
Copy
@ARTICLE{e86-c_12_2371,
author={Hirokazu KAWABATA, Hiroshi TANPO, Yoshio KOBAYASHI, },
journal={IEICE TRANSACTIONS on Electronics},
title={An Improvement of the Perturbation Method Using a TM010 Mode Cylindrical Cavity},
year={2003},
volume={E86-C},
number={12},
pages={2371-2378},
abstract={Effects of the sample insertion holes of the TM010 mode cylindrical cavity are analyzed on the basis of rigorous analysis by the Ritz-Galerkin method. The measurement accuracy of complex permittivity is examined by comparing the values by the perturbation method with ones by the rigorous analysis. Charts of relative errors Δ ε/εp and Δ tan δ/tan δp are presented, which are useful to measure the complex permittivity accurately by the perturbation method. The present analysis extends the validity of the conventional perturbation method.},
keywords={},
doi={},
ISSN={},
month={December},}
Copy
TY - JOUR
TI - An Improvement of the Perturbation Method Using a TM010 Mode Cylindrical Cavity
T2 - IEICE TRANSACTIONS on Electronics
SP - 2371
EP - 2378
AU - Hirokazu KAWABATA
AU - Hiroshi TANPO
AU - Yoshio KOBAYASHI
PY - 2003
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E86-C
IS - 12
JA - IEICE TRANSACTIONS on Electronics
Y1 - December 2003
AB - Effects of the sample insertion holes of the TM010 mode cylindrical cavity are analyzed on the basis of rigorous analysis by the Ritz-Galerkin method. The measurement accuracy of complex permittivity is examined by comparing the values by the perturbation method with ones by the rigorous analysis. Charts of relative errors Δ ε/εp and Δ tan δ/tan δp are presented, which are useful to measure the complex permittivity accurately by the perturbation method. The present analysis extends the validity of the conventional perturbation method.
ER -