Two type measurement methods of the unloaded Q-factor of a microwave resonator, the insertion loss method and the return loss method, are reexamined theoretically and compared experimentally. An error formula is derived to estimate the errors between the unloaded Q-factors measured by the two different methods. Measured results of a stripline resonator verified well the derived formula, and proved that the return loss method is more accurate and reliable than the traditional insertion loss method.

Publication
IEICE TRANSACTIONS on Electronics Vol.E86-C No.8 pp.1672-1677
Publication Date
2003/08/01
Publicized
Online ISSN
DOI
Type of Manuscript
Special Section PAPER (Special Issue on Microwave and Millimeter Wave Technology)