Organic electronics devices can be applicable to implant sensors. The noises in the acquired data can be removed by smoothing using sliding windows. We developed a new criterion for window-size decision based on smoothness and similarity (SSC). The smoothed curve fits the raw data well and is sufficiently smooth.
Kenichi SHIBATA
Yokohama National University
Takashi AMEMIYA
Yokohama National University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Kenichi SHIBATA, Takashi AMEMIYA, "How to Decide Window-Sizes of Smoothing Methods: A Goodness of Fit Criterion for Smoothing Oscillation Data" in IEICE TRANSACTIONS on Electronics,
vol. E102-C, no. 2, pp. 143-146, February 2019, doi: 10.1587/transele.2018OMS0003.
Abstract: Organic electronics devices can be applicable to implant sensors. The noises in the acquired data can be removed by smoothing using sliding windows. We developed a new criterion for window-size decision based on smoothness and similarity (SSC). The smoothed curve fits the raw data well and is sufficiently smooth.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.2018OMS0003/_p
Copy
@ARTICLE{e102-c_2_143,
author={Kenichi SHIBATA, Takashi AMEMIYA, },
journal={IEICE TRANSACTIONS on Electronics},
title={How to Decide Window-Sizes of Smoothing Methods: A Goodness of Fit Criterion for Smoothing Oscillation Data},
year={2019},
volume={E102-C},
number={2},
pages={143-146},
abstract={Organic electronics devices can be applicable to implant sensors. The noises in the acquired data can be removed by smoothing using sliding windows. We developed a new criterion for window-size decision based on smoothness and similarity (SSC). The smoothed curve fits the raw data well and is sufficiently smooth.},
keywords={},
doi={10.1587/transele.2018OMS0003},
ISSN={1745-1353},
month={February},}
Copy
TY - JOUR
TI - How to Decide Window-Sizes of Smoothing Methods: A Goodness of Fit Criterion for Smoothing Oscillation Data
T2 - IEICE TRANSACTIONS on Electronics
SP - 143
EP - 146
AU - Kenichi SHIBATA
AU - Takashi AMEMIYA
PY - 2019
DO - 10.1587/transele.2018OMS0003
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E102-C
IS - 2
JA - IEICE TRANSACTIONS on Electronics
Y1 - February 2019
AB - Organic electronics devices can be applicable to implant sensors. The noises in the acquired data can be removed by smoothing using sliding windows. We developed a new criterion for window-size decision based on smoothness and similarity (SSC). The smoothed curve fits the raw data well and is sufficiently smooth.
ER -