Influence of Arc Discharge on Contact Resistance of AgNi Contacts for Electromagnetic Contactors

Kiyoshi YOSHIDA, Koichiro SAWA, Kenji SUZUKI, Masaaki WATANABE

  • Full Text Views

    0

  • Cite this

Summary :

Experiments were carried out at several voltages to clarify the influence of the voltage on various characteristics, i.e. arc duration, contact resistance, arc energy, and the change in electrode mass. The voltage was varied from DC100 V to 160 V, the load current was fixed at 5 A constant, and the electromagnetic contactor was operated continuously up to 100,000 times. The experiments were carried out under the three operation modes which are classified by the arc discharge. As a result, the relation between the operation mode and contact resistance was clarified. When only a make arc was generated, the contact resistance was smallest. In addition, the contact resistance was not affected by the source voltage.

Publication
IEICE TRANSACTIONS on Electronics Vol.E95-C No.9 pp.1531-1534
Publication Date
2012/09/01
Publicized
Online ISSN
1745-1353
DOI
10.1587/transele.E95.C.1531
Type of Manuscript
BRIEF PAPER
Category

Authors

Keyword