The contact surface of a loose connector has both contact resistance and low inductance, and the inductance depends on the distribution of the true contacts. The contact resistance and inductance were measured by time-domain reflectometry (TDR) for seven contact distribution models. The resistance was approximately constant, while the maximum inductance varied more than twofold depending on the distribution model.
Kazuya UEHARA
Tohoku University
Yu-ichi HAYASHI
Tohoku University
Takaaki MIZUKI
Tohoku University
Hideaki SONE
Tohoku University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Kazuya UEHARA, Yu-ichi HAYASHI, Takaaki MIZUKI, Hideaki SONE, "Evaluation of Resistance and Inductance of Loose Connector Contact" in IEICE TRANSACTIONS on Electronics,
vol. E96-C, no. 9, pp. 1148-1150, September 2013, doi: 10.1587/transele.E96.C.1148.
Abstract: The contact surface of a loose connector has both contact resistance and low inductance, and the inductance depends on the distribution of the true contacts. The contact resistance and inductance were measured by time-domain reflectometry (TDR) for seven contact distribution models. The resistance was approximately constant, while the maximum inductance varied more than twofold depending on the distribution model.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.E96.C.1148/_p
Copy
@ARTICLE{e96-c_9_1148,
author={Kazuya UEHARA, Yu-ichi HAYASHI, Takaaki MIZUKI, Hideaki SONE, },
journal={IEICE TRANSACTIONS on Electronics},
title={Evaluation of Resistance and Inductance of Loose Connector Contact},
year={2013},
volume={E96-C},
number={9},
pages={1148-1150},
abstract={The contact surface of a loose connector has both contact resistance and low inductance, and the inductance depends on the distribution of the true contacts. The contact resistance and inductance were measured by time-domain reflectometry (TDR) for seven contact distribution models. The resistance was approximately constant, while the maximum inductance varied more than twofold depending on the distribution model.},
keywords={},
doi={10.1587/transele.E96.C.1148},
ISSN={1745-1353},
month={September},}
Copy
TY - JOUR
TI - Evaluation of Resistance and Inductance of Loose Connector Contact
T2 - IEICE TRANSACTIONS on Electronics
SP - 1148
EP - 1150
AU - Kazuya UEHARA
AU - Yu-ichi HAYASHI
AU - Takaaki MIZUKI
AU - Hideaki SONE
PY - 2013
DO - 10.1587/transele.E96.C.1148
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E96-C
IS - 9
JA - IEICE TRANSACTIONS on Electronics
Y1 - September 2013
AB - The contact surface of a loose connector has both contact resistance and low inductance, and the inductance depends on the distribution of the true contacts. The contact resistance and inductance were measured by time-domain reflectometry (TDR) for seven contact distribution models. The resistance was approximately constant, while the maximum inductance varied more than twofold depending on the distribution model.
ER -