An attenuation correction method was proposed for laser-produced plasma emission computed tomography (ECT), which is based on a relation of the attenuation coefficient and the emission coefficient in plasma. Simulation results show that the reconstructed images are dramatically improved in comparison to the reconstructions without attenuation correction.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Yen-Wei CHEN, Zensho NAKAO, Shinichi TAMURA, "Attenuation Correction for X-Ray Emission Computed Tomography of Laser-Produced Plasma" in IEICE TRANSACTIONS on Fundamentals,
vol. E79-A, no. 8, pp. 1287-1290, August 1996, doi: .
Abstract: An attenuation correction method was proposed for laser-produced plasma emission computed tomography (ECT), which is based on a relation of the attenuation coefficient and the emission coefficient in plasma. Simulation results show that the reconstructed images are dramatically improved in comparison to the reconstructions without attenuation correction.
URL: https://global.ieice.org/en_transactions/fundamentals/10.1587/e79-a_8_1287/_p
Copy
@ARTICLE{e79-a_8_1287,
author={Yen-Wei CHEN, Zensho NAKAO, Shinichi TAMURA, },
journal={IEICE TRANSACTIONS on Fundamentals},
title={Attenuation Correction for X-Ray Emission Computed Tomography of Laser-Produced Plasma},
year={1996},
volume={E79-A},
number={8},
pages={1287-1290},
abstract={An attenuation correction method was proposed for laser-produced plasma emission computed tomography (ECT), which is based on a relation of the attenuation coefficient and the emission coefficient in plasma. Simulation results show that the reconstructed images are dramatically improved in comparison to the reconstructions without attenuation correction.},
keywords={},
doi={},
ISSN={},
month={August},}
Copy
TY - JOUR
TI - Attenuation Correction for X-Ray Emission Computed Tomography of Laser-Produced Plasma
T2 - IEICE TRANSACTIONS on Fundamentals
SP - 1287
EP - 1290
AU - Yen-Wei CHEN
AU - Zensho NAKAO
AU - Shinichi TAMURA
PY - 1996
DO -
JO - IEICE TRANSACTIONS on Fundamentals
SN -
VL - E79-A
IS - 8
JA - IEICE TRANSACTIONS on Fundamentals
Y1 - August 1996
AB - An attenuation correction method was proposed for laser-produced plasma emission computed tomography (ECT), which is based on a relation of the attenuation coefficient and the emission coefficient in plasma. Simulation results show that the reconstructed images are dramatically improved in comparison to the reconstructions without attenuation correction.
ER -