We investigated the dependence of the desired echo return loss on frequency for various hands-free telecommunication conditions by subjective assessment. The desired echo return loss as a function of frequency (DERLf) is an important factor in the design and performance evaluation of a subband echo canceller, and it is a measure of what is considered an acceptable echo caused by electrical loss in the transmission line. The DERLf during single-talk was obtained as attenuated band-limited echo levels that subjects did not find objectionable when listening to the near-end speech and its band-limited echo under various hands-free telecommunication conditions. When we investigated the DERLf during double-talk, subjects also heard the speech in the far-end room from a loudspeaker. The echo was limited to a 250-Hz bandwidth assuming the use of a subband echo canceller. The test results showed that: (1) when the transmission delay was short (30 ms), the echo component around 2 to 3 kHz was the most objectionable to listeners; (2) as the transmission delay rose to 300 ms, the echo component around 1 kHz became the most objectionable; (3) when the room reverberation time was relatively long (about 500 ms), the echo component around 1 kHz was the most objectionable, even if the transmission delay was short; and (4) the DERLf during double-talk was about 5 to 10 dB lower than that during single-talk. Use of these DERLf values will enable the design of more efficient subband echo cancellers.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Sumitaka SAKAUCHI, Yoichi HANEDA, Shoji MAKINO, Masashi TANAKA, Yutaka KANEDA, "Subjective Assessment of the Desired Echo Return Loss for Subband Acoustic Echo Cancellers" in IEICE TRANSACTIONS on Fundamentals,
vol. E83-A, no. 12, pp. 2633-2639, December 2000, doi: .
Abstract: We investigated the dependence of the desired echo return loss on frequency for various hands-free telecommunication conditions by subjective assessment. The desired echo return loss as a function of frequency (DERLf) is an important factor in the design and performance evaluation of a subband echo canceller, and it is a measure of what is considered an acceptable echo caused by electrical loss in the transmission line. The DERLf during single-talk was obtained as attenuated band-limited echo levels that subjects did not find objectionable when listening to the near-end speech and its band-limited echo under various hands-free telecommunication conditions. When we investigated the DERLf during double-talk, subjects also heard the speech in the far-end room from a loudspeaker. The echo was limited to a 250-Hz bandwidth assuming the use of a subband echo canceller. The test results showed that: (1) when the transmission delay was short (30 ms), the echo component around 2 to 3 kHz was the most objectionable to listeners; (2) as the transmission delay rose to 300 ms, the echo component around 1 kHz became the most objectionable; (3) when the room reverberation time was relatively long (about 500 ms), the echo component around 1 kHz was the most objectionable, even if the transmission delay was short; and (4) the DERLf during double-talk was about 5 to 10 dB lower than that during single-talk. Use of these DERLf values will enable the design of more efficient subband echo cancellers.
URL: https://global.ieice.org/en_transactions/fundamentals/10.1587/e83-a_12_2633/_p
Copy
@ARTICLE{e83-a_12_2633,
author={Sumitaka SAKAUCHI, Yoichi HANEDA, Shoji MAKINO, Masashi TANAKA, Yutaka KANEDA, },
journal={IEICE TRANSACTIONS on Fundamentals},
title={Subjective Assessment of the Desired Echo Return Loss for Subband Acoustic Echo Cancellers},
year={2000},
volume={E83-A},
number={12},
pages={2633-2639},
abstract={We investigated the dependence of the desired echo return loss on frequency for various hands-free telecommunication conditions by subjective assessment. The desired echo return loss as a function of frequency (DERLf) is an important factor in the design and performance evaluation of a subband echo canceller, and it is a measure of what is considered an acceptable echo caused by electrical loss in the transmission line. The DERLf during single-talk was obtained as attenuated band-limited echo levels that subjects did not find objectionable when listening to the near-end speech and its band-limited echo under various hands-free telecommunication conditions. When we investigated the DERLf during double-talk, subjects also heard the speech in the far-end room from a loudspeaker. The echo was limited to a 250-Hz bandwidth assuming the use of a subband echo canceller. The test results showed that: (1) when the transmission delay was short (30 ms), the echo component around 2 to 3 kHz was the most objectionable to listeners; (2) as the transmission delay rose to 300 ms, the echo component around 1 kHz became the most objectionable; (3) when the room reverberation time was relatively long (about 500 ms), the echo component around 1 kHz was the most objectionable, even if the transmission delay was short; and (4) the DERLf during double-talk was about 5 to 10 dB lower than that during single-talk. Use of these DERLf values will enable the design of more efficient subband echo cancellers.},
keywords={},
doi={},
ISSN={},
month={December},}
Copy
TY - JOUR
TI - Subjective Assessment of the Desired Echo Return Loss for Subband Acoustic Echo Cancellers
T2 - IEICE TRANSACTIONS on Fundamentals
SP - 2633
EP - 2639
AU - Sumitaka SAKAUCHI
AU - Yoichi HANEDA
AU - Shoji MAKINO
AU - Masashi TANAKA
AU - Yutaka KANEDA
PY - 2000
DO -
JO - IEICE TRANSACTIONS on Fundamentals
SN -
VL - E83-A
IS - 12
JA - IEICE TRANSACTIONS on Fundamentals
Y1 - December 2000
AB - We investigated the dependence of the desired echo return loss on frequency for various hands-free telecommunication conditions by subjective assessment. The desired echo return loss as a function of frequency (DERLf) is an important factor in the design and performance evaluation of a subband echo canceller, and it is a measure of what is considered an acceptable echo caused by electrical loss in the transmission line. The DERLf during single-talk was obtained as attenuated band-limited echo levels that subjects did not find objectionable when listening to the near-end speech and its band-limited echo under various hands-free telecommunication conditions. When we investigated the DERLf during double-talk, subjects also heard the speech in the far-end room from a loudspeaker. The echo was limited to a 250-Hz bandwidth assuming the use of a subband echo canceller. The test results showed that: (1) when the transmission delay was short (30 ms), the echo component around 2 to 3 kHz was the most objectionable to listeners; (2) as the transmission delay rose to 300 ms, the echo component around 1 kHz became the most objectionable; (3) when the room reverberation time was relatively long (about 500 ms), the echo component around 1 kHz was the most objectionable, even if the transmission delay was short; and (4) the DERLf during double-talk was about 5 to 10 dB lower than that during single-talk. Use of these DERLf values will enable the design of more efficient subband echo cancellers.
ER -