Most of the current research is focused on the row-column scanning keyboard interface for English letter and number input. At the present time, there are insufficient methods to control the computer mouse effectively. In this study, a categorized row-column scanning computer interface is developed to improve the conventional single key-in row-column scanning method. The beneficial developments include: speed enhancement by categorizing radicals of keyboard, input control of mouse, and multiple selection of input methods such as surface electromyographic (SEMG) control, breath pressure sensibility control with puff, force sensibility control, infrared sensibility control and single key-in control. Meanwhile, an enhancement software package is developed to increase the row-column scanning keyboard capabilities and to upgrade the completeness of the computer mouse for the disabled persons to control the operation of data entry and the associated implementation better.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Yu-Luen CHEN, Ying-Ying SHIH, "A Categorized Row-Column Scanning Computer Interface for the Disabled" in IEICE TRANSACTIONS on Information,
vol. E84-D, no. 9, pp. 1198-1205, September 2001, doi: .
Abstract: Most of the current research is focused on the row-column scanning keyboard interface for English letter and number input. At the present time, there are insufficient methods to control the computer mouse effectively. In this study, a categorized row-column scanning computer interface is developed to improve the conventional single key-in row-column scanning method. The beneficial developments include: speed enhancement by categorizing radicals of keyboard, input control of mouse, and multiple selection of input methods such as surface electromyographic (SEMG) control, breath pressure sensibility control with puff, force sensibility control, infrared sensibility control and single key-in control. Meanwhile, an enhancement software package is developed to increase the row-column scanning keyboard capabilities and to upgrade the completeness of the computer mouse for the disabled persons to control the operation of data entry and the associated implementation better.
URL: https://global.ieice.org/en_transactions/information/10.1587/e84-d_9_1198/_p
Copy
@ARTICLE{e84-d_9_1198,
author={Yu-Luen CHEN, Ying-Ying SHIH, },
journal={IEICE TRANSACTIONS on Information},
title={A Categorized Row-Column Scanning Computer Interface for the Disabled},
year={2001},
volume={E84-D},
number={9},
pages={1198-1205},
abstract={Most of the current research is focused on the row-column scanning keyboard interface for English letter and number input. At the present time, there are insufficient methods to control the computer mouse effectively. In this study, a categorized row-column scanning computer interface is developed to improve the conventional single key-in row-column scanning method. The beneficial developments include: speed enhancement by categorizing radicals of keyboard, input control of mouse, and multiple selection of input methods such as surface electromyographic (SEMG) control, breath pressure sensibility control with puff, force sensibility control, infrared sensibility control and single key-in control. Meanwhile, an enhancement software package is developed to increase the row-column scanning keyboard capabilities and to upgrade the completeness of the computer mouse for the disabled persons to control the operation of data entry and the associated implementation better.},
keywords={},
doi={},
ISSN={},
month={September},}
Copy
TY - JOUR
TI - A Categorized Row-Column Scanning Computer Interface for the Disabled
T2 - IEICE TRANSACTIONS on Information
SP - 1198
EP - 1205
AU - Yu-Luen CHEN
AU - Ying-Ying SHIH
PY - 2001
DO -
JO - IEICE TRANSACTIONS on Information
SN -
VL - E84-D
IS - 9
JA - IEICE TRANSACTIONS on Information
Y1 - September 2001
AB - Most of the current research is focused on the row-column scanning keyboard interface for English letter and number input. At the present time, there are insufficient methods to control the computer mouse effectively. In this study, a categorized row-column scanning computer interface is developed to improve the conventional single key-in row-column scanning method. The beneficial developments include: speed enhancement by categorizing radicals of keyboard, input control of mouse, and multiple selection of input methods such as surface electromyographic (SEMG) control, breath pressure sensibility control with puff, force sensibility control, infrared sensibility control and single key-in control. Meanwhile, an enhancement software package is developed to increase the row-column scanning keyboard capabilities and to upgrade the completeness of the computer mouse for the disabled persons to control the operation of data entry and the associated implementation better.
ER -