Break operations of DC inductive (L=20mH) load currents up to about 5A with 14V were conducted in air with AgSnO2 contact pairs under different contact opening speeds, first up to 20mm/s and then to 200mm/s. Average break arc duration at each current level was calculated under the respective opening speeds. While break arc durations became shorter with increases in the opening speeds at larger current levels, such reduction tendencies were less significant with an increase of the contact opening speed from 20mm/s to 200mm/s, even when operated to break a load current of 5A. Both load current levels and contact opening speed levels seem to exhibit certain roles for realizing arc shortening effects.
In order to study the influences of contact opening speeds on arc extinction gap length characteristics, Ag contacts were operated to break DC inductive load currents from 0.1 A to 2.0 A at 14 V with contact opening speeds of 0.5 mm/s, 1 mm/s, 2 mm/s, 5 mm/s and 10 mm/s in a switching mechanism employing a stepping motor, and arc voltage waveforms were observed at each opening of the contacts. From the results, the average arc durations were determined at each current level under the respective contact opening speeds, and the average arc extinction gap lengths were calculated by multiplying the average arc duration value and the contact opening speed value. It was found that average arc durations showed no significant differences with increasing contact opening speeds. Thus, arc extinction gaps became larger at faster opening speeds in the inductive load conditions of this study.