In order to study the influences of contact opening speeds on arc extinction gap length characteristics, Ag contacts were operated to break DC inductive load currents from 0.1 A to 2.0 A at 14 V with contact opening speeds of 0.5 mm/s, 1 mm/s, 2 mm/s, 5 mm/s and 10 mm/s in a switching mechanism employing a stepping motor, and arc voltage waveforms were observed at each opening of the contacts. From the results, the average arc durations were determined at each current level under the respective contact opening speeds, and the average arc extinction gap lengths were calculated by multiplying the average arc duration value and the contact opening speed value. It was found that average arc durations showed no significant differences with increasing contact opening speeds. Thus, arc extinction gaps became larger at faster opening speeds in the inductive load conditions of this study.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Makoto HASEGAWA, "Relationships between Contact Opening Speeds and Arc Extinction Gap Lengths at Break of Silver Contacts" in IEICE TRANSACTIONS on Electronics,
vol. E94-C, no. 9, pp. 1435-1438, September 2011, doi: 10.1587/transele.E94.C.1435.
Abstract: In order to study the influences of contact opening speeds on arc extinction gap length characteristics, Ag contacts were operated to break DC inductive load currents from 0.1 A to 2.0 A at 14 V with contact opening speeds of 0.5 mm/s, 1 mm/s, 2 mm/s, 5 mm/s and 10 mm/s in a switching mechanism employing a stepping motor, and arc voltage waveforms were observed at each opening of the contacts. From the results, the average arc durations were determined at each current level under the respective contact opening speeds, and the average arc extinction gap lengths were calculated by multiplying the average arc duration value and the contact opening speed value. It was found that average arc durations showed no significant differences with increasing contact opening speeds. Thus, arc extinction gaps became larger at faster opening speeds in the inductive load conditions of this study.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.E94.C.1435/_p
Copy
@ARTICLE{e94-c_9_1435,
author={Makoto HASEGAWA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Relationships between Contact Opening Speeds and Arc Extinction Gap Lengths at Break of Silver Contacts},
year={2011},
volume={E94-C},
number={9},
pages={1435-1438},
abstract={In order to study the influences of contact opening speeds on arc extinction gap length characteristics, Ag contacts were operated to break DC inductive load currents from 0.1 A to 2.0 A at 14 V with contact opening speeds of 0.5 mm/s, 1 mm/s, 2 mm/s, 5 mm/s and 10 mm/s in a switching mechanism employing a stepping motor, and arc voltage waveforms were observed at each opening of the contacts. From the results, the average arc durations were determined at each current level under the respective contact opening speeds, and the average arc extinction gap lengths were calculated by multiplying the average arc duration value and the contact opening speed value. It was found that average arc durations showed no significant differences with increasing contact opening speeds. Thus, arc extinction gaps became larger at faster opening speeds in the inductive load conditions of this study.},
keywords={},
doi={10.1587/transele.E94.C.1435},
ISSN={1745-1353},
month={September},}
Copy
TY - JOUR
TI - Relationships between Contact Opening Speeds and Arc Extinction Gap Lengths at Break of Silver Contacts
T2 - IEICE TRANSACTIONS on Electronics
SP - 1435
EP - 1438
AU - Makoto HASEGAWA
PY - 2011
DO - 10.1587/transele.E94.C.1435
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E94-C
IS - 9
JA - IEICE TRANSACTIONS on Electronics
Y1 - September 2011
AB - In order to study the influences of contact opening speeds on arc extinction gap length characteristics, Ag contacts were operated to break DC inductive load currents from 0.1 A to 2.0 A at 14 V with contact opening speeds of 0.5 mm/s, 1 mm/s, 2 mm/s, 5 mm/s and 10 mm/s in a switching mechanism employing a stepping motor, and arc voltage waveforms were observed at each opening of the contacts. From the results, the average arc durations were determined at each current level under the respective contact opening speeds, and the average arc extinction gap lengths were calculated by multiplying the average arc duration value and the contact opening speed value. It was found that average arc durations showed no significant differences with increasing contact opening speeds. Thus, arc extinction gaps became larger at faster opening speeds in the inductive load conditions of this study.
ER -