  • Experimental Study on Arc Motion and Voltage Fluctuation at Slowly Separating Contact with External DC Magnetic Field

    Yoshiki KAYANO  Kazuaki MIYANAGA  Hiroshi INOUE  

     
    BRIEF PAPER

      Vol:
    E97-C No:9
      Page(s):
    858-862

    Since electromagnetic (EM) noise resulting from an arc discharge disturbs other electric devices, parameters on electromagnetic compatibility, as well as lifetime and reliability, are important properties for electrical contacts. To clarify the characteristics and the mechanism of the generation of the EM noise, the arc column and voltage fluctuations generated by slowly breaking contacts with external direct current (DC) magnetic field, up to 20,mT, was investigated experimentally using Ag$_{90.7{ m wt%}}$SnO$_{2,9.3{ m wt}%}$ material. Firstly the motion of the arc column is measured by high-speed camera. Secondary, the distribution of the motion of the arc and contact voltage are discussed. It was revealed that the contact voltage fluctuation in the arc duration is related to the arc column motion.

  • Experimental Analysis of Arc Waveform Affected by Holder Temperature Change at Slowly Separation of Silver-Tin Dioxide Contacts

    Yoshiki KAYANO  Kazuaki MIYANAGA  Hiroshi INOUE  

     
    PAPER

      Vol:
    E96-C No:9
      Page(s):
    1110-1118

    Arc discharge at breaking electrical contact is considered as a main source of not only degradation of the electrical property but also an undesired electromagnetic (EM) noise. In order to clarify the effect of holder temperature on the bridge and arc-duration, opening-waveforms at slowly separating silver-tin dioxide contact with different holder temperature are measured and discussed experimentally in this paper. Firstly, as opening-waveforms, the contact voltage, the contact current and the movement of moving contact related to the gap length are measured simultaneously. Secondly, the relationship between temperature of the holder and duration of the arc was quantified experimentally. It was revealed that as the initial temperature of the holder becomes higher, arc-duration becomes slightly longer. More importantly, the holder temperature dependencies of percentage of each-phase (metallic and gaseous-phases) are different with different closed-current.

  • Voltage Waveform at Slowly Separating Silver-Based Contacts with Heated Holder

    Yoshiki KAYANO  Kazuaki MIYANAGA  Hiroshi INOUE  

     
    PAPER

      Vol:
    E95-C No:9
      Page(s):
    1495-1501

    Arc discharge generated by breaking electrical contact is considered as a main source of not only degradation of the electrical property but also an undesired electromagnetic (EM) noise. In order to clarify the effect of heated temperature on the bridge, arc-duration and the fluctuation of voltage, opening-waveforms at slowly separating silver-tin dioxide contact with holder heating are measured and discussed experimentally in this paper. Firstly, opening-waveforms are measured. Secondly, voltage fluctuation of the each arc-phase is discussed to extract the effect of the heated holder. The relationship between temperature of the heated holder and duration and fluctuation of the arc was investigated experimentally. It was revealed that as the initial temperature of the heated holder becomes higher, arc-duration becomes slightly longer. In addition, voltage fluctuation at the gaseous-phase decreases when the holder is heated. Consequently, the heated holder can suppress the voltage fluctuation even if its duration becomes slightly longer.