  • Electric Measurement of Melting Phenomena for Breaking Relay Contacts

    Noboru WAKATSUKI  Nobuo TAKATSU  Masahiro OIKAWA  

     
    PAPER-Arc Discharge & Contact Phenomena

      Vol:
    E92-C No:8
      Page(s):
    998-1002

    Using the transient current switch circuit in parallel with the energizing switching contacts for timely control of breaking operation, the increase of contact voltage is suppressed at the last stage of the breaking of electric contacts. Breaking contact voltage Vc and current Ic of electromagnetic relays with Ag contacting electrodes were measured with 12.5-50 V and 0.1-20 A for two hinge springs (Spring constants; 2 N/mm and 0.2 N/mm). The current-decreasing process was clearly measured at the melting voltage Um. After Vc=Um, the breaking time of contact current did not depend on mechanical motion controlled by the two hinge springs and energizing power-supply voltage, but depended on the contact current. The residue of melt electrode was observed optically as a white fusion spot, with radius depending on the energizing current.

  • Analytical Model of Melting Phenomena for Breaking Relay Contacts

    Noboru WAKATSUKI  Nobuo TAKATSU  Toshiteru MAEDA  Takayuki KUDO  

     
    PAPER-Arc Discharge & Contact Phenomena

      Vol:
    E92-C No:8
      Page(s):
    1003-1007

    Using the transient current switch circuit in parallel with the energizing contacts, the slow decay of the contact current due to thermal fusion of metal was observed just after the contact voltage exceeded the melting contact voltage Um. At that time, the contact voltage was higher than the boiling contact voltage Ub. These results contradict Holm's θ theory. A new melting model of breaking mechanical contact is proposed. The area surrounding a cluster of contacting a-spots melts, the melt metal diffuses, and the contact spot thermally shrinks. Including the metal phase transition from solid to liquid, the increase of contact resistance is introduced to the electric circuit analysis. The numerical analysis agrees qualitatively with measured V-I characteristics.

  • Breaking Contact Phenomena of a Time-coordinated Non-arcing Relay

    Noboru WAKATSUKI  Hiroshi HONMA  

     
    PAPER-Contact Phenomena

      Vol:
    E91-C No:8
      Page(s):
    1206-1210

    VI time responses of a conventional electromagnetic relay during breaking contact operations were measured. In a conventional switching circuit, unstable contact resistance, irregular bouncing, and poor reproducibility were confirmed. Using a transient current switch circuit and two sharpened contact electrodes, bouncing during a breaking operation was suppressed, and unstable contact resistance changes and reproducibility of breaking operation were also improved.