Using the transient current switch circuit in parallel with the energizing contacts, the slow decay of the contact current due to thermal fusion of metal was observed just after the contact voltage exceeded the melting contact voltage Um. At that time, the contact voltage was higher than the boiling contact voltage Ub. These results contradict Holm's
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Noboru WAKATSUKI, Nobuo TAKATSU, Toshiteru MAEDA, Takayuki KUDO, "Analytical Model of Melting Phenomena for Breaking Relay Contacts" in IEICE TRANSACTIONS on Electronics,
vol. E92-C, no. 8, pp. 1003-1007, August 2009, doi: 10.1587/transele.E92.C.1003.
Abstract: Using the transient current switch circuit in parallel with the energizing contacts, the slow decay of the contact current due to thermal fusion of metal was observed just after the contact voltage exceeded the melting contact voltage Um. At that time, the contact voltage was higher than the boiling contact voltage Ub. These results contradict Holm's
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.E92.C.1003/_p
Copy
@ARTICLE{e92-c_8_1003,
author={Noboru WAKATSUKI, Nobuo TAKATSU, Toshiteru MAEDA, Takayuki KUDO, },
journal={IEICE TRANSACTIONS on Electronics},
title={Analytical Model of Melting Phenomena for Breaking Relay Contacts},
year={2009},
volume={E92-C},
number={8},
pages={1003-1007},
abstract={Using the transient current switch circuit in parallel with the energizing contacts, the slow decay of the contact current due to thermal fusion of metal was observed just after the contact voltage exceeded the melting contact voltage Um. At that time, the contact voltage was higher than the boiling contact voltage Ub. These results contradict Holm's
keywords={},
doi={10.1587/transele.E92.C.1003},
ISSN={1745-1353},
month={August},}
Copy
TY - JOUR
TI - Analytical Model of Melting Phenomena for Breaking Relay Contacts
T2 - IEICE TRANSACTIONS on Electronics
SP - 1003
EP - 1007
AU - Noboru WAKATSUKI
AU - Nobuo TAKATSU
AU - Toshiteru MAEDA
AU - Takayuki KUDO
PY - 2009
DO - 10.1587/transele.E92.C.1003
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E92-C
IS - 8
JA - IEICE TRANSACTIONS on Electronics
Y1 - August 2009
AB - Using the transient current switch circuit in parallel with the energizing contacts, the slow decay of the contact current due to thermal fusion of metal was observed just after the contact voltage exceeded the melting contact voltage Um. At that time, the contact voltage was higher than the boiling contact voltage Ub. These results contradict Holm's
ER -