Anechoic chambers have been effectively used for microwave propagation, electromagnetic interference (EMI) and immunity testing. The electromagnetic compatibility (EMC) problem has recently become serious and many of these chambers have been constructed. The results of a questionnaire survey sent to anechoic chamber manufacturers are described that a total of 450 anechoic chambers have been constructed in Japan since 1964. Twenty years ago the purpose of the chambers was microwave propagation research, but more than 50 each year have recently being built for EMC/EMI and immunity testing. Their size has gradually been reduced by the use of absorbing materials such as ferrite with dielectric materials. The lowest frequency of most chambers is 30MHz for the 3 m method of site attenuation.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Yasutaka SHIMIZU, "Anechoic Chambers for EMI Test" in IEICE TRANSACTIONS on Communications,
vol. E75-B, no. 3, pp. 101-106, March 1992, doi: .
Abstract: Anechoic chambers have been effectively used for microwave propagation, electromagnetic interference (EMI) and immunity testing. The electromagnetic compatibility (EMC) problem has recently become serious and many of these chambers have been constructed. The results of a questionnaire survey sent to anechoic chamber manufacturers are described that a total of 450 anechoic chambers have been constructed in Japan since 1964. Twenty years ago the purpose of the chambers was microwave propagation research, but more than 50 each year have recently being built for EMC/EMI and immunity testing. Their size has gradually been reduced by the use of absorbing materials such as ferrite with dielectric materials. The lowest frequency of most chambers is 30MHz for the 3 m method of site attenuation.
URL: https://global.ieice.org/en_transactions/communications/10.1587/e75-b_3_101/_p
Copy
@ARTICLE{e75-b_3_101,
author={Yasutaka SHIMIZU, },
journal={IEICE TRANSACTIONS on Communications},
title={Anechoic Chambers for EMI Test},
year={1992},
volume={E75-B},
number={3},
pages={101-106},
abstract={Anechoic chambers have been effectively used for microwave propagation, electromagnetic interference (EMI) and immunity testing. The electromagnetic compatibility (EMC) problem has recently become serious and many of these chambers have been constructed. The results of a questionnaire survey sent to anechoic chamber manufacturers are described that a total of 450 anechoic chambers have been constructed in Japan since 1964. Twenty years ago the purpose of the chambers was microwave propagation research, but more than 50 each year have recently being built for EMC/EMI and immunity testing. Their size has gradually been reduced by the use of absorbing materials such as ferrite with dielectric materials. The lowest frequency of most chambers is 30MHz for the 3 m method of site attenuation.},
keywords={},
doi={},
ISSN={},
month={March},}
Copy
TY - JOUR
TI - Anechoic Chambers for EMI Test
T2 - IEICE TRANSACTIONS on Communications
SP - 101
EP - 106
AU - Yasutaka SHIMIZU
PY - 1992
DO -
JO - IEICE TRANSACTIONS on Communications
SN -
VL - E75-B
IS - 3
JA - IEICE TRANSACTIONS on Communications
Y1 - March 1992
AB - Anechoic chambers have been effectively used for microwave propagation, electromagnetic interference (EMI) and immunity testing. The electromagnetic compatibility (EMC) problem has recently become serious and many of these chambers have been constructed. The results of a questionnaire survey sent to anechoic chamber manufacturers are described that a total of 450 anechoic chambers have been constructed in Japan since 1964. Twenty years ago the purpose of the chambers was microwave propagation research, but more than 50 each year have recently being built for EMC/EMI and immunity testing. Their size has gradually been reduced by the use of absorbing materials such as ferrite with dielectric materials. The lowest frequency of most chambers is 30MHz for the 3 m method of site attenuation.