The search functionality is under construction.

IEICE TRANSACTIONS on Communications

Field Uniformity and Correlation Coefficient Analysis of KRISS Reverberation Chamber

Aditia Nur BAKTI, No-Weon KANG, Jae-Yong KWON

  • Full Text Views

    0

  • Cite this

Summary :

Reverberation chambers (RCs) are used widely in the electromagnetic measurement area. An RC is designed to have a long reverberation time, generate numerous modes, and provide good field uniformity within the chamber. The purpose of this paper is to describe the design process and measurement of the KRISS Reverberation Chamber (KRC). KRC models with 4.5m × 3.4m × 2.8m dimensions are simulated by 3D numerical simulation software. The field uniformity and correlation coefficient are then analyzed at 200MHz to obtain the optimized model. The simulation results show good performance in terms of field uniformity and are confirmed by measurement from 200MHz to 1GHz. The lowest usable frequency (LUF) of KRC was confirmed by field uniformity to be 200MHz. However, the stirrer correlation coefficient results show good performance above 300MHz.

Publication
IEICE TRANSACTIONS on Communications Vol.E101-B No.11 pp.2289-2296
Publication Date
2018/11/01
Publicized
2018/04/25
Online ISSN
1745-1345
DOI
10.1587/transcom.2017EBP3460
Type of Manuscript
PAPER
Category
Electromagnetic Compatibility(EMC)

Authors

Aditia Nur BAKTI
  University of Science and Technology
No-Weon KANG
  Korea Research Institute of Standards and Science
Jae-Yong KWON
  University of Science and Technology,Korea Research Institute of Standards and Science

Keyword