A novel sensing system for glucose in aqueous solution based on cataluminescence(CTL) is proposed. CTL is a kind of chemiluminescence emitted in a course of catalytic oxidation of combustible substances. A sensing system consisting of a CTL-based chemical-sensor made of the γ-Al2O3 catalyst activated with Tb and an ultrasonic nebulizer is developed. CTL is emitted by injection of air containing mist of a glucose solution prepared by the nebulizer on the catalyst. The CTL intensity measured by a photomultiplier is reproducible for the repeated injection of the mist, and the system can measure glucose concentration in a range of 1-200 mg/dl.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Masahiro OZAKI, Tohru OKABAYASHI, Teppei ISHIMARU, Nobuhiko YAMASHITA, Masuo NAKAGAWA, "A Novel Sensing System for Glucose in a Solution Based on Cataluminescence" in IEICE TRANSACTIONS on Electronics,
vol. E89-C, no. 12, pp. 1792-1795, December 2006, doi: 10.1093/ietele/e89-c.12.1792.
Abstract: A novel sensing system for glucose in aqueous solution based on cataluminescence(CTL) is proposed. CTL is a kind of chemiluminescence emitted in a course of catalytic oxidation of combustible substances. A sensing system consisting of a CTL-based chemical-sensor made of the γ-Al2O3 catalyst activated with Tb and an ultrasonic nebulizer is developed. CTL is emitted by injection of air containing mist of a glucose solution prepared by the nebulizer on the catalyst. The CTL intensity measured by a photomultiplier is reproducible for the repeated injection of the mist, and the system can measure glucose concentration in a range of 1-200 mg/dl.
URL: https://global.ieice.org/en_transactions/electronics/10.1093/ietele/e89-c.12.1792/_p
Copy
@ARTICLE{e89-c_12_1792,
author={Masahiro OZAKI, Tohru OKABAYASHI, Teppei ISHIMARU, Nobuhiko YAMASHITA, Masuo NAKAGAWA, },
journal={IEICE TRANSACTIONS on Electronics},
title={A Novel Sensing System for Glucose in a Solution Based on Cataluminescence},
year={2006},
volume={E89-C},
number={12},
pages={1792-1795},
abstract={A novel sensing system for glucose in aqueous solution based on cataluminescence(CTL) is proposed. CTL is a kind of chemiluminescence emitted in a course of catalytic oxidation of combustible substances. A sensing system consisting of a CTL-based chemical-sensor made of the γ-Al2O3 catalyst activated with Tb and an ultrasonic nebulizer is developed. CTL is emitted by injection of air containing mist of a glucose solution prepared by the nebulizer on the catalyst. The CTL intensity measured by a photomultiplier is reproducible for the repeated injection of the mist, and the system can measure glucose concentration in a range of 1-200 mg/dl.},
keywords={},
doi={10.1093/ietele/e89-c.12.1792},
ISSN={1745-1353},
month={December},}
Copy
TY - JOUR
TI - A Novel Sensing System for Glucose in a Solution Based on Cataluminescence
T2 - IEICE TRANSACTIONS on Electronics
SP - 1792
EP - 1795
AU - Masahiro OZAKI
AU - Tohru OKABAYASHI
AU - Teppei ISHIMARU
AU - Nobuhiko YAMASHITA
AU - Masuo NAKAGAWA
PY - 2006
DO - 10.1093/ietele/e89-c.12.1792
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E89-C
IS - 12
JA - IEICE TRANSACTIONS on Electronics
Y1 - December 2006
AB - A novel sensing system for glucose in aqueous solution based on cataluminescence(CTL) is proposed. CTL is a kind of chemiluminescence emitted in a course of catalytic oxidation of combustible substances. A sensing system consisting of a CTL-based chemical-sensor made of the γ-Al2O3 catalyst activated with Tb and an ultrasonic nebulizer is developed. CTL is emitted by injection of air containing mist of a glucose solution prepared by the nebulizer on the catalyst. The CTL intensity measured by a photomultiplier is reproducible for the repeated injection of the mist, and the system can measure glucose concentration in a range of 1-200 mg/dl.
ER -