Time-Resolved Spectroscopic Temperature Measurement of Break Arcs in a D.C.42 V Resistive Circuit

Junya SEKIKAWA, Naoki MORIYAMA, Takayoshi KUBONO

  • Full Text Views

    0

  • Cite this

Summary :

In a D.C.42 V-10A resistive circuit, break arcs are generated between electrical contact pairs. The materials of the contact pairs are Ag, Ag/C 2wt%, Ag/SnO2 12wt%, and Ag/ZnO 12wt%. The arc spectral intensities are measured by a time-resolved spectroscopic temperature measurement system. The arc temperature is calculated from the spectral intensities by using the method of relative intensities of two spectra. The experimental results are as follows. The arc temperature gradually decreases with increase of the gap of electrical contacts. The ranges of arc temperature for Ag, Ag/C 2wt%, Ag/SnO2 12wt%, and Ag/ZnO 12wt% contacts pairs are 4500-11000 K, 4000-6000 K, 4000-7000 K, and 4000-11000 K, respectively.

Publication
IEICE TRANSACTIONS on Electronics Vol.E91-C No.8 pp.1268-1272
Publication Date
2008/08/01
Publicized
Online ISSN
1745-1353
DOI
10.1093/ietele/e91-c.8.1268
Type of Manuscript
Special Section PAPER (Special Section on Recent Development of Electromechanical Devices(Selected Papers from IS-EMD2007))
Category
Arc Discharge & Related Phenomena

Authors

Keyword