The minimum transferable linewidth by X-ray is derived using waveguide analysis. The minimum width is determined by the refractive index of the absorber and does not depend on the X-ray wavelength. Therefore there is an optimum mask aperture size which provides the minimum linewidth. By using Au as the absorber, 8 nm linewidth is attainable.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Masaki TAKAKUWA, Kazuhito FURUYA, "The Analysis of Waveguiding Effects on the Minimum Transferable Linewidth of an Ultrafine X-Ray Mask" in IEICE TRANSACTIONS on Electronics,
vol. E76-C, no. 4, pp. 594-599, April 1993, doi: .
Abstract: The minimum transferable linewidth by X-ray is derived using waveguide analysis. The minimum width is determined by the refractive index of the absorber and does not depend on the X-ray wavelength. Therefore there is an optimum mask aperture size which provides the minimum linewidth. By using Au as the absorber, 8 nm linewidth is attainable.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e76-c_4_594/_p
Copy
@ARTICLE{e76-c_4_594,
author={Masaki TAKAKUWA, Kazuhito FURUYA, },
journal={IEICE TRANSACTIONS on Electronics},
title={The Analysis of Waveguiding Effects on the Minimum Transferable Linewidth of an Ultrafine X-Ray Mask},
year={1993},
volume={E76-C},
number={4},
pages={594-599},
abstract={The minimum transferable linewidth by X-ray is derived using waveguide analysis. The minimum width is determined by the refractive index of the absorber and does not depend on the X-ray wavelength. Therefore there is an optimum mask aperture size which provides the minimum linewidth. By using Au as the absorber, 8 nm linewidth is attainable.},
keywords={},
doi={},
ISSN={},
month={April},}
Copy
TY - JOUR
TI - The Analysis of Waveguiding Effects on the Minimum Transferable Linewidth of an Ultrafine X-Ray Mask
T2 - IEICE TRANSACTIONS on Electronics
SP - 594
EP - 599
AU - Masaki TAKAKUWA
AU - Kazuhito FURUYA
PY - 1993
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E76-C
IS - 4
JA - IEICE TRANSACTIONS on Electronics
Y1 - April 1993
AB - The minimum transferable linewidth by X-ray is derived using waveguide analysis. The minimum width is determined by the refractive index of the absorber and does not depend on the X-ray wavelength. Therefore there is an optimum mask aperture size which provides the minimum linewidth. By using Au as the absorber, 8 nm linewidth is attainable.
ER -