A rigorous analysis for a TM010 mode cylindrical cavity with insertion holes is presented on the basis of the Ritz-Galerkin method to realize accurate measurements of the complex permittivity of liquid. The effects of sample insertion holes, a dielectric tube, and air-gaps between a dielectric tube and sample insertion holes are taken into account in this analysis. The validity of this method is verified from measured results of some kinds of liquid.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Hirokazu KAWABATA, Hiroshi TANPO, Yoshio KOBAYASHI, "Analysis and Experiments of a TM010 Mode Cylindrical Cavity to Measure Accurate Complex Permittivity of Liquid" in IEICE TRANSACTIONS on Electronics,
vol. E87-C, no. 5, pp. 694-699, May 2004, doi: .
Abstract: A rigorous analysis for a TM010 mode cylindrical cavity with insertion holes is presented on the basis of the Ritz-Galerkin method to realize accurate measurements of the complex permittivity of liquid. The effects of sample insertion holes, a dielectric tube, and air-gaps between a dielectric tube and sample insertion holes are taken into account in this analysis. The validity of this method is verified from measured results of some kinds of liquid.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e87-c_5_694/_p
Copy
@ARTICLE{e87-c_5_694,
author={Hirokazu KAWABATA, Hiroshi TANPO, Yoshio KOBAYASHI, },
journal={IEICE TRANSACTIONS on Electronics},
title={Analysis and Experiments of a TM010 Mode Cylindrical Cavity to Measure Accurate Complex Permittivity of Liquid},
year={2004},
volume={E87-C},
number={5},
pages={694-699},
abstract={A rigorous analysis for a TM010 mode cylindrical cavity with insertion holes is presented on the basis of the Ritz-Galerkin method to realize accurate measurements of the complex permittivity of liquid. The effects of sample insertion holes, a dielectric tube, and air-gaps between a dielectric tube and sample insertion holes are taken into account in this analysis. The validity of this method is verified from measured results of some kinds of liquid.},
keywords={},
doi={},
ISSN={},
month={May},}
Copy
TY - JOUR
TI - Analysis and Experiments of a TM010 Mode Cylindrical Cavity to Measure Accurate Complex Permittivity of Liquid
T2 - IEICE TRANSACTIONS on Electronics
SP - 694
EP - 699
AU - Hirokazu KAWABATA
AU - Hiroshi TANPO
AU - Yoshio KOBAYASHI
PY - 2004
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E87-C
IS - 5
JA - IEICE TRANSACTIONS on Electronics
Y1 - May 2004
AB - A rigorous analysis for a TM010 mode cylindrical cavity with insertion holes is presented on the basis of the Ritz-Galerkin method to realize accurate measurements of the complex permittivity of liquid. The effects of sample insertion holes, a dielectric tube, and air-gaps between a dielectric tube and sample insertion holes are taken into account in this analysis. The validity of this method is verified from measured results of some kinds of liquid.
ER -