The reliability of electromagnetic relay (EMR) which contains a permanent magnet (PM) can be improved by a robust design method. In this parameter design process, the calculation of electromagnetic system is very important. In analytical calculation, PM is often equivalent to a lumped parameter model of one magnetic resistance and one magnetic potential, but significant error is often caused; in order to increase the accuracy, a distributed parameter calculation model (DPM) of PM bar is established; solution procedure as well as verification condition of this model is given; by a case study of the single PM bar, magnetic field lines division method is adopted to build the DPM, the starting point and section magnetic flux of each segment are solved, a comparison is made with finite element method (FEM) and measured data; the accuracy of this magnetic field line based distributed parameter model (MFDPM) in PM bar is verified; this model is applied to the electromagnetic system of a certain type EMR, electromagnetic system calculation model is established based on MFDPM, and the static force is calculated under different rotation angles; compared with traditional lumped parameter model and FEM, it proves to be of acceptable calculation accuracy and high calculation speed which fit the requirement of robust design.
Huimin LIANG
Harbin Institute of Technology
Jiaxin YOU
Harbin Institute of Technology
Zhaowen CAI
G&A Technologies Co. Ltd.
Guofu ZHAI
Harbin Institute of Technology
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Huimin LIANG, Jiaxin YOU, Zhaowen CAI, Guofu ZHAI, "Research on Distributed Parameter Model of Permanent Magnet in Robust Design of Electromagnetic Relay" in IEICE TRANSACTIONS on Electronics,
vol. E97-C, no. 12, pp. 1142-1149, December 2014, doi: 10.1587/transele.E97.C.1142.
Abstract: The reliability of electromagnetic relay (EMR) which contains a permanent magnet (PM) can be improved by a robust design method. In this parameter design process, the calculation of electromagnetic system is very important. In analytical calculation, PM is often equivalent to a lumped parameter model of one magnetic resistance and one magnetic potential, but significant error is often caused; in order to increase the accuracy, a distributed parameter calculation model (DPM) of PM bar is established; solution procedure as well as verification condition of this model is given; by a case study of the single PM bar, magnetic field lines division method is adopted to build the DPM, the starting point and section magnetic flux of each segment are solved, a comparison is made with finite element method (FEM) and measured data; the accuracy of this magnetic field line based distributed parameter model (MFDPM) in PM bar is verified; this model is applied to the electromagnetic system of a certain type EMR, electromagnetic system calculation model is established based on MFDPM, and the static force is calculated under different rotation angles; compared with traditional lumped parameter model and FEM, it proves to be of acceptable calculation accuracy and high calculation speed which fit the requirement of robust design.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.E97.C.1142/_p
Copy
@ARTICLE{e97-c_12_1142,
author={Huimin LIANG, Jiaxin YOU, Zhaowen CAI, Guofu ZHAI, },
journal={IEICE TRANSACTIONS on Electronics},
title={Research on Distributed Parameter Model of Permanent Magnet in Robust Design of Electromagnetic Relay},
year={2014},
volume={E97-C},
number={12},
pages={1142-1149},
abstract={The reliability of electromagnetic relay (EMR) which contains a permanent magnet (PM) can be improved by a robust design method. In this parameter design process, the calculation of electromagnetic system is very important. In analytical calculation, PM is often equivalent to a lumped parameter model of one magnetic resistance and one magnetic potential, but significant error is often caused; in order to increase the accuracy, a distributed parameter calculation model (DPM) of PM bar is established; solution procedure as well as verification condition of this model is given; by a case study of the single PM bar, magnetic field lines division method is adopted to build the DPM, the starting point and section magnetic flux of each segment are solved, a comparison is made with finite element method (FEM) and measured data; the accuracy of this magnetic field line based distributed parameter model (MFDPM) in PM bar is verified; this model is applied to the electromagnetic system of a certain type EMR, electromagnetic system calculation model is established based on MFDPM, and the static force is calculated under different rotation angles; compared with traditional lumped parameter model and FEM, it proves to be of acceptable calculation accuracy and high calculation speed which fit the requirement of robust design.},
keywords={},
doi={10.1587/transele.E97.C.1142},
ISSN={1745-1353},
month={December},}
Copy
TY - JOUR
TI - Research on Distributed Parameter Model of Permanent Magnet in Robust Design of Electromagnetic Relay
T2 - IEICE TRANSACTIONS on Electronics
SP - 1142
EP - 1149
AU - Huimin LIANG
AU - Jiaxin YOU
AU - Zhaowen CAI
AU - Guofu ZHAI
PY - 2014
DO - 10.1587/transele.E97.C.1142
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E97-C
IS - 12
JA - IEICE TRANSACTIONS on Electronics
Y1 - December 2014
AB - The reliability of electromagnetic relay (EMR) which contains a permanent magnet (PM) can be improved by a robust design method. In this parameter design process, the calculation of electromagnetic system is very important. In analytical calculation, PM is often equivalent to a lumped parameter model of one magnetic resistance and one magnetic potential, but significant error is often caused; in order to increase the accuracy, a distributed parameter calculation model (DPM) of PM bar is established; solution procedure as well as verification condition of this model is given; by a case study of the single PM bar, magnetic field lines division method is adopted to build the DPM, the starting point and section magnetic flux of each segment are solved, a comparison is made with finite element method (FEM) and measured data; the accuracy of this magnetic field line based distributed parameter model (MFDPM) in PM bar is verified; this model is applied to the electromagnetic system of a certain type EMR, electromagnetic system calculation model is established based on MFDPM, and the static force is calculated under different rotation angles; compared with traditional lumped parameter model and FEM, it proves to be of acceptable calculation accuracy and high calculation speed which fit the requirement of robust design.
ER -