To improve measurement accuracy and speed, a switched-capacitor capacitance measurement circuit with the vernier scale is developed. Its process consists of a coarse measurement by charge-balancing A-D conversion and a fine measurement by single-slope A-D conversion. a prototype using discrete components confirms the principles of operation.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Kazuyuki KONDO, Kenzo WATANABE, "A Switched-Capacitor Capacitance Measurement Circuit with the Vernier Scale" in IEICE TRANSACTIONS on Fundamentals,
vol. E76-A, no. 7, pp. 1139-1142, July 1993, doi: .
Abstract: To improve measurement accuracy and speed, a switched-capacitor capacitance measurement circuit with the vernier scale is developed. Its process consists of a coarse measurement by charge-balancing A-D conversion and a fine measurement by single-slope A-D conversion. a prototype using discrete components confirms the principles of operation.
URL: https://global.ieice.org/en_transactions/fundamentals/10.1587/e76-a_7_1139/_p
Copy
@ARTICLE{e76-a_7_1139,
author={Kazuyuki KONDO, Kenzo WATANABE, },
journal={IEICE TRANSACTIONS on Fundamentals},
title={A Switched-Capacitor Capacitance Measurement Circuit with the Vernier Scale},
year={1993},
volume={E76-A},
number={7},
pages={1139-1142},
abstract={To improve measurement accuracy and speed, a switched-capacitor capacitance measurement circuit with the vernier scale is developed. Its process consists of a coarse measurement by charge-balancing A-D conversion and a fine measurement by single-slope A-D conversion. a prototype using discrete components confirms the principles of operation.},
keywords={},
doi={},
ISSN={},
month={July},}
Copy
TY - JOUR
TI - A Switched-Capacitor Capacitance Measurement Circuit with the Vernier Scale
T2 - IEICE TRANSACTIONS on Fundamentals
SP - 1139
EP - 1142
AU - Kazuyuki KONDO
AU - Kenzo WATANABE
PY - 1993
DO -
JO - IEICE TRANSACTIONS on Fundamentals
SN -
VL - E76-A
IS - 7
JA - IEICE TRANSACTIONS on Fundamentals
Y1 - July 1993
AB - To improve measurement accuracy and speed, a switched-capacitor capacitance measurement circuit with the vernier scale is developed. Its process consists of a coarse measurement by charge-balancing A-D conversion and a fine measurement by single-slope A-D conversion. a prototype using discrete components confirms the principles of operation.
ER -