In the case of miniaturized telemetry capsules, such as a capsule endoscope that can acquire and transmit images from the intestines, the size and the power consumption of the module are restricted. In the capsule endoscopes, it is desirable that the control function can capacitate the sampling of digestive fluid and tissue, drug delivery, and locomotion. In this paper, the control function was embodied by bi-directional communication. A CPLD (complex programmable logic device) controller was designed and implemented for the bi-directional communication in capsule endoscope. The diameter of capsule was 12 mm and the length was 30 mm. The performance of implemented capsule was verified by in-vivo animal experiments.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
JyungHyun LEE, YeonKwan MOON, YoungHo YOON, HeeJoon PARK, ChulHo WON, HyunChul CHOI, JinHo CHO, "CPLD Based Bi-Directional Wireless Capsule Endoscopes" in IEICE TRANSACTIONS on Information,
vol. E90-D, no. 3, pp. 694-697, March 2007, doi: 10.1093/ietisy/e90-d.3.694.
Abstract: In the case of miniaturized telemetry capsules, such as a capsule endoscope that can acquire and transmit images from the intestines, the size and the power consumption of the module are restricted. In the capsule endoscopes, it is desirable that the control function can capacitate the sampling of digestive fluid and tissue, drug delivery, and locomotion. In this paper, the control function was embodied by bi-directional communication. A CPLD (complex programmable logic device) controller was designed and implemented for the bi-directional communication in capsule endoscope. The diameter of capsule was 12 mm and the length was 30 mm. The performance of implemented capsule was verified by in-vivo animal experiments.
URL: https://global.ieice.org/en_transactions/information/10.1093/ietisy/e90-d.3.694/_p
Copy
@ARTICLE{e90-d_3_694,
author={JyungHyun LEE, YeonKwan MOON, YoungHo YOON, HeeJoon PARK, ChulHo WON, HyunChul CHOI, JinHo CHO, },
journal={IEICE TRANSACTIONS on Information},
title={CPLD Based Bi-Directional Wireless Capsule Endoscopes},
year={2007},
volume={E90-D},
number={3},
pages={694-697},
abstract={In the case of miniaturized telemetry capsules, such as a capsule endoscope that can acquire and transmit images from the intestines, the size and the power consumption of the module are restricted. In the capsule endoscopes, it is desirable that the control function can capacitate the sampling of digestive fluid and tissue, drug delivery, and locomotion. In this paper, the control function was embodied by bi-directional communication. A CPLD (complex programmable logic device) controller was designed and implemented for the bi-directional communication in capsule endoscope. The diameter of capsule was 12 mm and the length was 30 mm. The performance of implemented capsule was verified by in-vivo animal experiments.},
keywords={},
doi={10.1093/ietisy/e90-d.3.694},
ISSN={1745-1361},
month={March},}
Copy
TY - JOUR
TI - CPLD Based Bi-Directional Wireless Capsule Endoscopes
T2 - IEICE TRANSACTIONS on Information
SP - 694
EP - 697
AU - JyungHyun LEE
AU - YeonKwan MOON
AU - YoungHo YOON
AU - HeeJoon PARK
AU - ChulHo WON
AU - HyunChul CHOI
AU - JinHo CHO
PY - 2007
DO - 10.1093/ietisy/e90-d.3.694
JO - IEICE TRANSACTIONS on Information
SN - 1745-1361
VL - E90-D
IS - 3
JA - IEICE TRANSACTIONS on Information
Y1 - March 2007
AB - In the case of miniaturized telemetry capsules, such as a capsule endoscope that can acquire and transmit images from the intestines, the size and the power consumption of the module are restricted. In the capsule endoscopes, it is desirable that the control function can capacitate the sampling of digestive fluid and tissue, drug delivery, and locomotion. In this paper, the control function was embodied by bi-directional communication. A CPLD (complex programmable logic device) controller was designed and implemented for the bi-directional communication in capsule endoscope. The diameter of capsule was 12 mm and the length was 30 mm. The performance of implemented capsule was verified by in-vivo animal experiments.
ER -