Image Registration can be seen as an optimization problem to find a cost function and then use an optimization method to get its minimum. Normalized mutual information is a widely-used robust method to design a cost function in medical image registration. Its calculation is based on the joint histogram of the fixed and transformed moving images. Usually, only a discrete joint histogram is considered in the calculation of normalized mutual information. The discrete joint histogram does not allow the cost function to be explicitly differentiated, so it can only use non-gradient based optimization methods, such as Powell's method, to seek the minimum. In this paper, a parzen-window based method is proposed to estimate the continuous joint histogram in order to make it possible to derive the close form solution for the derivative of the cost function. With this help, we successfully apply the gradient-based optimization method in registration. We also design a new kernel for the parzen-window based method. Our designed kernel is a second order polynomial kernel with the width of two. Because of good theoretical characteristics, this kernel works better than other kernels, such as a cubic B-spline kernel and a first order B-spline kernel, which are widely used in the parzen-window based estimation. Both rigid and non-rigid registration experiments are done to show improved behavior of our designed kernel. Additionally, the proposed method is successfully applied to a clinical CT-MR non-rigid registration which is able to assist a magnetic resonance (MR) guided microwave thermocoagulation of liver tumors.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Rui XU, Yen-Wei CHEN, Song-Yuan TANG, Shigehiro MORIKAWA, Yoshimasa KURUMI, "Parzen-Window Based Normalized Mutual Information for Medical Image Registration" in IEICE TRANSACTIONS on Information,
vol. E91-D, no. 1, pp. 132-144, January 2008, doi: 10.1093/ietisy/e91-d.1.132.
Abstract: Image Registration can be seen as an optimization problem to find a cost function and then use an optimization method to get its minimum. Normalized mutual information is a widely-used robust method to design a cost function in medical image registration. Its calculation is based on the joint histogram of the fixed and transformed moving images. Usually, only a discrete joint histogram is considered in the calculation of normalized mutual information. The discrete joint histogram does not allow the cost function to be explicitly differentiated, so it can only use non-gradient based optimization methods, such as Powell's method, to seek the minimum. In this paper, a parzen-window based method is proposed to estimate the continuous joint histogram in order to make it possible to derive the close form solution for the derivative of the cost function. With this help, we successfully apply the gradient-based optimization method in registration. We also design a new kernel for the parzen-window based method. Our designed kernel is a second order polynomial kernel with the width of two. Because of good theoretical characteristics, this kernel works better than other kernels, such as a cubic B-spline kernel and a first order B-spline kernel, which are widely used in the parzen-window based estimation. Both rigid and non-rigid registration experiments are done to show improved behavior of our designed kernel. Additionally, the proposed method is successfully applied to a clinical CT-MR non-rigid registration which is able to assist a magnetic resonance (MR) guided microwave thermocoagulation of liver tumors.
URL: https://global.ieice.org/en_transactions/information/10.1093/ietisy/e91-d.1.132/_p
Copy
@ARTICLE{e91-d_1_132,
author={Rui XU, Yen-Wei CHEN, Song-Yuan TANG, Shigehiro MORIKAWA, Yoshimasa KURUMI, },
journal={IEICE TRANSACTIONS on Information},
title={Parzen-Window Based Normalized Mutual Information for Medical Image Registration},
year={2008},
volume={E91-D},
number={1},
pages={132-144},
abstract={Image Registration can be seen as an optimization problem to find a cost function and then use an optimization method to get its minimum. Normalized mutual information is a widely-used robust method to design a cost function in medical image registration. Its calculation is based on the joint histogram of the fixed and transformed moving images. Usually, only a discrete joint histogram is considered in the calculation of normalized mutual information. The discrete joint histogram does not allow the cost function to be explicitly differentiated, so it can only use non-gradient based optimization methods, such as Powell's method, to seek the minimum. In this paper, a parzen-window based method is proposed to estimate the continuous joint histogram in order to make it possible to derive the close form solution for the derivative of the cost function. With this help, we successfully apply the gradient-based optimization method in registration. We also design a new kernel for the parzen-window based method. Our designed kernel is a second order polynomial kernel with the width of two. Because of good theoretical characteristics, this kernel works better than other kernels, such as a cubic B-spline kernel and a first order B-spline kernel, which are widely used in the parzen-window based estimation. Both rigid and non-rigid registration experiments are done to show improved behavior of our designed kernel. Additionally, the proposed method is successfully applied to a clinical CT-MR non-rigid registration which is able to assist a magnetic resonance (MR) guided microwave thermocoagulation of liver tumors.},
keywords={},
doi={10.1093/ietisy/e91-d.1.132},
ISSN={1745-1361},
month={January},}
Copy
TY - JOUR
TI - Parzen-Window Based Normalized Mutual Information for Medical Image Registration
T2 - IEICE TRANSACTIONS on Information
SP - 132
EP - 144
AU - Rui XU
AU - Yen-Wei CHEN
AU - Song-Yuan TANG
AU - Shigehiro MORIKAWA
AU - Yoshimasa KURUMI
PY - 2008
DO - 10.1093/ietisy/e91-d.1.132
JO - IEICE TRANSACTIONS on Information
SN - 1745-1361
VL - E91-D
IS - 1
JA - IEICE TRANSACTIONS on Information
Y1 - January 2008
AB - Image Registration can be seen as an optimization problem to find a cost function and then use an optimization method to get its minimum. Normalized mutual information is a widely-used robust method to design a cost function in medical image registration. Its calculation is based on the joint histogram of the fixed and transformed moving images. Usually, only a discrete joint histogram is considered in the calculation of normalized mutual information. The discrete joint histogram does not allow the cost function to be explicitly differentiated, so it can only use non-gradient based optimization methods, such as Powell's method, to seek the minimum. In this paper, a parzen-window based method is proposed to estimate the continuous joint histogram in order to make it possible to derive the close form solution for the derivative of the cost function. With this help, we successfully apply the gradient-based optimization method in registration. We also design a new kernel for the parzen-window based method. Our designed kernel is a second order polynomial kernel with the width of two. Because of good theoretical characteristics, this kernel works better than other kernels, such as a cubic B-spline kernel and a first order B-spline kernel, which are widely used in the parzen-window based estimation. Both rigid and non-rigid registration experiments are done to show improved behavior of our designed kernel. Additionally, the proposed method is successfully applied to a clinical CT-MR non-rigid registration which is able to assist a magnetic resonance (MR) guided microwave thermocoagulation of liver tumors.