In Chirp-Pulse Microwave Computed Tomography (CP-MCT) the images are affected by the blur which is inherent to the measurement principle and is described by a space-variant Point Spread Function (PSF). In this paper we investigate the PSF of CP-MCT including the space dependence both experimentally and computationally. The experimental evaluation is performed by measuring the projections of a target consisting of a thin low-loss dielectric rod surrounded by a saline solution and placed at various positions in the measuring region. On the other hand, the theoretical evaluation is obtained by computing the projections of the same target via a numerical solution of Maxwell's equations. Since CP-MCT uses a chirp signal, the numerical evaluation is carried out by the use of a FD-TD method. The projections of the rod could be obtained by computing the field during the sweep time of the chirp signal for each position of the receiving antenna. Since this procedure is extremely time consuming, we compute the impulse response function of the system by exciting the transmitting antenna with a wide-band Gaussian pulse. Then the signal transmitted in CP-MCT is obtained by computing the convolution product in time domain of the input chirp pulse with the impulse response function of the system. We find a good agreement between measured and computed PSF. The rationality of the computed PSF is verified by three distinct ways and the usefulness of this function is shown by a remarkable effect in the restoration of CP-MCT images. Knowledge on the space-variant PSF will be utilized for more accurate image deblurring in CP-MCT.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Michio MIYAKAWA, Kentaroh ORIKASA, Mario BERTERO, "Evaluation of the Response Function and Its Space Dependence in Chirp Pulse Microwave Computed Tomography (CP-MCT)" in IEICE TRANSACTIONS on Information,
vol. E85-D, no. 1, pp. 52-59, January 2002, doi: .
Abstract: In Chirp-Pulse Microwave Computed Tomography (CP-MCT) the images are affected by the blur which is inherent to the measurement principle and is described by a space-variant Point Spread Function (PSF). In this paper we investigate the PSF of CP-MCT including the space dependence both experimentally and computationally. The experimental evaluation is performed by measuring the projections of a target consisting of a thin low-loss dielectric rod surrounded by a saline solution and placed at various positions in the measuring region. On the other hand, the theoretical evaluation is obtained by computing the projections of the same target via a numerical solution of Maxwell's equations. Since CP-MCT uses a chirp signal, the numerical evaluation is carried out by the use of a FD-TD method. The projections of the rod could be obtained by computing the field during the sweep time of the chirp signal for each position of the receiving antenna. Since this procedure is extremely time consuming, we compute the impulse response function of the system by exciting the transmitting antenna with a wide-band Gaussian pulse. Then the signal transmitted in CP-MCT is obtained by computing the convolution product in time domain of the input chirp pulse with the impulse response function of the system. We find a good agreement between measured and computed PSF. The rationality of the computed PSF is verified by three distinct ways and the usefulness of this function is shown by a remarkable effect in the restoration of CP-MCT images. Knowledge on the space-variant PSF will be utilized for more accurate image deblurring in CP-MCT.
URL: https://global.ieice.org/en_transactions/information/10.1587/e85-d_1_52/_p
Copy
@ARTICLE{e85-d_1_52,
author={Michio MIYAKAWA, Kentaroh ORIKASA, Mario BERTERO, },
journal={IEICE TRANSACTIONS on Information},
title={Evaluation of the Response Function and Its Space Dependence in Chirp Pulse Microwave Computed Tomography (CP-MCT)},
year={2002},
volume={E85-D},
number={1},
pages={52-59},
abstract={In Chirp-Pulse Microwave Computed Tomography (CP-MCT) the images are affected by the blur which is inherent to the measurement principle and is described by a space-variant Point Spread Function (PSF). In this paper we investigate the PSF of CP-MCT including the space dependence both experimentally and computationally. The experimental evaluation is performed by measuring the projections of a target consisting of a thin low-loss dielectric rod surrounded by a saline solution and placed at various positions in the measuring region. On the other hand, the theoretical evaluation is obtained by computing the projections of the same target via a numerical solution of Maxwell's equations. Since CP-MCT uses a chirp signal, the numerical evaluation is carried out by the use of a FD-TD method. The projections of the rod could be obtained by computing the field during the sweep time of the chirp signal for each position of the receiving antenna. Since this procedure is extremely time consuming, we compute the impulse response function of the system by exciting the transmitting antenna with a wide-band Gaussian pulse. Then the signal transmitted in CP-MCT is obtained by computing the convolution product in time domain of the input chirp pulse with the impulse response function of the system. We find a good agreement between measured and computed PSF. The rationality of the computed PSF is verified by three distinct ways and the usefulness of this function is shown by a remarkable effect in the restoration of CP-MCT images. Knowledge on the space-variant PSF will be utilized for more accurate image deblurring in CP-MCT.},
keywords={},
doi={},
ISSN={},
month={January},}
Copy
TY - JOUR
TI - Evaluation of the Response Function and Its Space Dependence in Chirp Pulse Microwave Computed Tomography (CP-MCT)
T2 - IEICE TRANSACTIONS on Information
SP - 52
EP - 59
AU - Michio MIYAKAWA
AU - Kentaroh ORIKASA
AU - Mario BERTERO
PY - 2002
DO -
JO - IEICE TRANSACTIONS on Information
SN -
VL - E85-D
IS - 1
JA - IEICE TRANSACTIONS on Information
Y1 - January 2002
AB - In Chirp-Pulse Microwave Computed Tomography (CP-MCT) the images are affected by the blur which is inherent to the measurement principle and is described by a space-variant Point Spread Function (PSF). In this paper we investigate the PSF of CP-MCT including the space dependence both experimentally and computationally. The experimental evaluation is performed by measuring the projections of a target consisting of a thin low-loss dielectric rod surrounded by a saline solution and placed at various positions in the measuring region. On the other hand, the theoretical evaluation is obtained by computing the projections of the same target via a numerical solution of Maxwell's equations. Since CP-MCT uses a chirp signal, the numerical evaluation is carried out by the use of a FD-TD method. The projections of the rod could be obtained by computing the field during the sweep time of the chirp signal for each position of the receiving antenna. Since this procedure is extremely time consuming, we compute the impulse response function of the system by exciting the transmitting antenna with a wide-band Gaussian pulse. Then the signal transmitted in CP-MCT is obtained by computing the convolution product in time domain of the input chirp pulse with the impulse response function of the system. We find a good agreement between measured and computed PSF. The rationality of the computed PSF is verified by three distinct ways and the usefulness of this function is shown by a remarkable effect in the restoration of CP-MCT images. Knowledge on the space-variant PSF will be utilized for more accurate image deblurring in CP-MCT.
ER -