Partial response is applied to an optical fiber transmission system with low fiber loss for the purpose of expanding repeater spacing beyond the range imposed by fiber bandwidth restriction. Detailed theoretical and experimental results on the relation between receiver power penalty and data rate to fiber bandwidth ratio are presented. Duobinary codes are preferable to non-return to zero full response codes, provided that the 3 dB fiber bandwidth is less than 0.6 times the data rate.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Susumu MACHIDA, "Partial Response Optical Fiber Transmission System" in IEICE TRANSACTIONS on transactions,
vol. E63-E, no. 10, pp. 746-753, October 1980, doi: .
Abstract: Partial response is applied to an optical fiber transmission system with low fiber loss for the purpose of expanding repeater spacing beyond the range imposed by fiber bandwidth restriction. Detailed theoretical and experimental results on the relation between receiver power penalty and data rate to fiber bandwidth ratio are presented. Duobinary codes are preferable to non-return to zero full response codes, provided that the 3 dB fiber bandwidth is less than 0.6 times the data rate.
URL: https://global.ieice.org/en_transactions/transactions/10.1587/e63-e_10_746/_p
Copy
@ARTICLE{e63-e_10_746,
author={Susumu MACHIDA, },
journal={IEICE TRANSACTIONS on transactions},
title={Partial Response Optical Fiber Transmission System},
year={1980},
volume={E63-E},
number={10},
pages={746-753},
abstract={Partial response is applied to an optical fiber transmission system with low fiber loss for the purpose of expanding repeater spacing beyond the range imposed by fiber bandwidth restriction. Detailed theoretical and experimental results on the relation between receiver power penalty and data rate to fiber bandwidth ratio are presented. Duobinary codes are preferable to non-return to zero full response codes, provided that the 3 dB fiber bandwidth is less than 0.6 times the data rate.},
keywords={},
doi={},
ISSN={},
month={October},}
Copy
TY - JOUR
TI - Partial Response Optical Fiber Transmission System
T2 - IEICE TRANSACTIONS on transactions
SP - 746
EP - 753
AU - Susumu MACHIDA
PY - 1980
DO -
JO - IEICE TRANSACTIONS on transactions
SN -
VL - E63-E
IS - 10
JA - IEICE TRANSACTIONS on transactions
Y1 - October 1980
AB - Partial response is applied to an optical fiber transmission system with low fiber loss for the purpose of expanding repeater spacing beyond the range imposed by fiber bandwidth restriction. Detailed theoretical and experimental results on the relation between receiver power penalty and data rate to fiber bandwidth ratio are presented. Duobinary codes are preferable to non-return to zero full response codes, provided that the 3 dB fiber bandwidth is less than 0.6 times the data rate.
ER -