An analytic expression of electromagnetic near field emitterd by a single current flow along a straight wire is derived to obtain the radiated EMI limit from the telecommunication lines connected to the equipment. The validity of the theory is tested in the experiment. Calculations show that the conversion factor between the electric field strength and the terminal voltage is not significantly changed by the wire length. A maximum conversion factor of about -30 dB in the frequency range of 0.1 -30 MHz is obtained.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Nobuo KUWABARA, Tsuyoshi IDEGUCHI, "Calculation of Near Field Emitting from Telecommunication Lines" in IEICE TRANSACTIONS on transactions,
vol. E70-E, no. 4, pp. 247-249, April 1987, doi: .
Abstract: An analytic expression of electromagnetic near field emitterd by a single current flow along a straight wire is derived to obtain the radiated EMI limit from the telecommunication lines connected to the equipment. The validity of the theory is tested in the experiment. Calculations show that the conversion factor between the electric field strength and the terminal voltage is not significantly changed by the wire length. A maximum conversion factor of about -30 dB in the frequency range of 0.1 -30 MHz is obtained.
URL: https://global.ieice.org/en_transactions/transactions/10.1587/e70-e_4_247/_p
Copy
@ARTICLE{e70-e_4_247,
author={Nobuo KUWABARA, Tsuyoshi IDEGUCHI, },
journal={IEICE TRANSACTIONS on transactions},
title={Calculation of Near Field Emitting from Telecommunication Lines},
year={1987},
volume={E70-E},
number={4},
pages={247-249},
abstract={An analytic expression of electromagnetic near field emitterd by a single current flow along a straight wire is derived to obtain the radiated EMI limit from the telecommunication lines connected to the equipment. The validity of the theory is tested in the experiment. Calculations show that the conversion factor between the electric field strength and the terminal voltage is not significantly changed by the wire length. A maximum conversion factor of about -30 dB in the frequency range of 0.1 -30 MHz is obtained.},
keywords={},
doi={},
ISSN={},
month={April},}
Copy
TY - JOUR
TI - Calculation of Near Field Emitting from Telecommunication Lines
T2 - IEICE TRANSACTIONS on transactions
SP - 247
EP - 249
AU - Nobuo KUWABARA
AU - Tsuyoshi IDEGUCHI
PY - 1987
DO -
JO - IEICE TRANSACTIONS on transactions
SN -
VL - E70-E
IS - 4
JA - IEICE TRANSACTIONS on transactions
Y1 - April 1987
AB - An analytic expression of electromagnetic near field emitterd by a single current flow along a straight wire is derived to obtain the radiated EMI limit from the telecommunication lines connected to the equipment. The validity of the theory is tested in the experiment. Calculations show that the conversion factor between the electric field strength and the terminal voltage is not significantly changed by the wire length. A maximum conversion factor of about -30 dB in the frequency range of 0.1 -30 MHz is obtained.
ER -