1-1hit |
Yasuhisa SATO Rinshi SUGINO Masaki OKUNO Toshiro NAKANISHI Takashi ITO
Breakdown fields and the charges to breakdown (QBD) of oxides increased after UV/Cl2 pre-oxidation cleaning. This is due to decreased residual metal contaminants on silicon surfaces in the bottom of the LOCOS region after wet cleaning. Treatment in NH4OH, H2O2 and H2O prior to UV/Cl2 cleaning suppressed increases in surface roughness and kept leakage currents through the oxides after UV/Cl2 cleaning as low as those after wet cleaning alone. The large junction leakage currents--caused by metal contaminants introduced during dry etching--decreased after UV/Cl2 cleaning which removes the contaminated layer.