The search functionality is under construction.
The search functionality is under construction.

Keyword Search Result

[Keyword] halation(3hit)

1-3hit
  • New Switching Control for Synchronous Rectifications in Low-Voltage Paralleled Converter System without Voltage and Current Fluctuations

    Hiroshi SHIMAMORI  Teruhiko KOHAMA  Tamotsu NINOMIYA  

     
    PAPER-Electronic Circuits

      Vol:
    E88-C No:3
      Page(s):
    395-402

    Paralleled converter system with synchronous rectifiers (SRs) causes several problems such as surge voltage, inhalation current and circulating current. Generally, the system stops operation of the SRs in light load to avoid these problems. However, simultaneously, large voltage fluctuations in the output of the modules are occurred due to forward voltage drop of diode. The fluctuations cause serious faults to the semiconductor devices working in very low voltage such as CPU and VLSI. Moreover, the voltage fluctuations generate unstable current fluctuations in the paralleled converter system with current-sharing control. This paper proposes new switching control methods for rectifiers to reduce the voltage and current fluctuations. The effectiveness of the proposed methods is confirmed by computer simulation and experimental results.

  • Important Factors to Convey High Order Sensation

    Makoto MIYAHARA  Takao INO  Hideki SHIRAI  Shuji TANIHO  Ralph ALGAZI  

     
    INVITED PAPER

      Vol:
    E81-B No:11
      Page(s):
    1966-1973

    The coming information society will require images at the high end of the quality range. By using a new method which focuses on the assessment words of the high order sensation, we are investigating the important physical factors for the difficult reproduction of high level, high quality sensation in the electronic capture and display of images. We have found a key assessment word "image depth" that describes appropriately the high order subjective sensation that is indispensable for the display of extra high quality images. Related to the depth of images, we have discovered a new physical factor and the degree of precision required of already known physical factors for the display of extra high quality images. The cross modulation among R, G and B signals is the newly discovered important physical factor affecting the quality of an electronic display. In addition, we have found that very strict control of distortion in the gamma and the step response and the strict suppression of the halation in a CRT display are necessary. We note that aliasing of the displayed images also destroys the sensation of depth. This paper first outlines the overall objective of our work, second considers the important physical factors as important for extra high quality imaging, and then describes the specific effects of cross modulation distortion, gamma, step response, halation and aliasing as they relate to image depth. Finally, the relation of the discussed physical factors with the high order sensation are discussed broadly.

  • An Optimization for Biological Compartment System

    Hirofumi HIRAYAMA  Norio TAKEUCHI  Yuzou FUKUYAMA  

     
    LETTER

      Vol:
    E77-A No:11
      Page(s):
    1896-1903

    An optimal control theory has been applied to a biological compartment system to show a method to analyze the control principle of biological system represented by compartments. Present theory has been proposed to afford a theoretical back ground and validity for the strategy of drug administration or control of the anesthetic agent in practical medicine. The instantaneous change of the concentration of a given material within a biological system has been expressed by differential equations. Each compartment has been set to be transferred a material from all other compartments and conversely each compartment sends it to all other compartments. The control input was restricted to be one kind. The performance function involved the deviation from the target value, the rate of change in concentration and the amount of the control variables. The biological system was defined to operate optimally only when the performance function has been minimized during a given time period. By the optimal control theory of Pontoriagin, above biological problem has been converted to a mathematical problem and was solved numerically by multiple shooting method. The calculated trajectory of the optimal control has been asymmetric parabolic one with the maximum at its initiation and the minimum at the middle of total reaction time. This pattern has been consistent with that of probable transient change of the concentration of anesthetic agent when it has been inhalated under the most up to date "Rapid Inhalation Induction" method. The optimal trasient change of the concentration at each compartment has beeb affected by the difference in time dependent nature and the magnitude of the transfer rate. Present theory afforded a method to analyze the control strategy of biological system expressed by compartments model and showed an availability for actual clinical medicine. The optimal control principle must be a most adequate one to describe the Homeostasis in biological system.