The search functionality is under construction.
The search functionality is under construction.

The Relationship between Voltage and Duration of Short-Time Arc Generated by Slowly Breaking Silver Contact

Yoshiki KAYANO, Hikaru MIURA, Kazuaki MIYANAGA, Hiroshi INOUE

  • Full Text Views

    0

  • Cite this

Summary :

Arc discharge generated by breaking electrical contact is considered as a main source of an undesired electromagnetic (EM) noise. To clarify mechanism of generation of the EM noise, feature extraction of bridge and short-time arc waveforms generated by slowly breaking Ag contact was discussed experimentally. The short-duration time arc before the ignition of the continuous metallic arc discharge was observed. The highest probability density voltage is defined as short-arc sustainable voltage (SASV). The relationship between SASV and duration of short-time arc was quantified experimentally. It is revealed that as the arc voltage of the short-time arc is higher, its duration becomes longer.

Publication
IEICE TRANSACTIONS on Electronics Vol.E91-C No.8 pp.1230-1232
Publication Date
2008/08/01
Publicized
Online ISSN
1745-1353
DOI
10.1093/ietele/e91-c.8.1230
Type of Manuscript
Special Section LETTER (Special Section on Recent Development of Electromechanical Devices(Selected Papers from IS-EMD2007))
Category
Arc Discharge & Related Phenomena

Authors

Keyword