The stability conditions and stability factors of terminated active two port networks are investigated. They are expressed with the S parameters of active devices and the radii and centers of the circles defined by source and load terminations. The stability conditions are applied to specific cases. Some of the results correspond to the stability conditions expressed in Z, Y, H or G parameters and one of the other stability conditions of terminated two port network is similar to that for passive terminations which is expressed in S parameters. The various results derived in this paper are very useful for checking the stability of amplifiers, because both stability conditions and stability factors are simply calculated by using the S parameters without using the graphical method or transforming S parameters to Z, Y, H or G parameters. These stability conditions can be also used even if negative input or output resistance appears and even if the real part of source or load immittance is negative.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Yoshihiro MIWA, "Stability of an Active Two Port Network in terms of S Parameters" in IEICE TRANSACTIONS on Electronics,
vol. E77-C, no. 3, pp. 498-509, March 1994, doi: .
Abstract: The stability conditions and stability factors of terminated active two port networks are investigated. They are expressed with the S parameters of active devices and the radii and centers of the circles defined by source and load terminations. The stability conditions are applied to specific cases. Some of the results correspond to the stability conditions expressed in Z, Y, H or G parameters and one of the other stability conditions of terminated two port network is similar to that for passive terminations which is expressed in S parameters. The various results derived in this paper are very useful for checking the stability of amplifiers, because both stability conditions and stability factors are simply calculated by using the S parameters without using the graphical method or transforming S parameters to Z, Y, H or G parameters. These stability conditions can be also used even if negative input or output resistance appears and even if the real part of source or load immittance is negative.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e77-c_3_498/_p
Copy
@ARTICLE{e77-c_3_498,
author={Yoshihiro MIWA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Stability of an Active Two Port Network in terms of S Parameters},
year={1994},
volume={E77-C},
number={3},
pages={498-509},
abstract={The stability conditions and stability factors of terminated active two port networks are investigated. They are expressed with the S parameters of active devices and the radii and centers of the circles defined by source and load terminations. The stability conditions are applied to specific cases. Some of the results correspond to the stability conditions expressed in Z, Y, H or G parameters and one of the other stability conditions of terminated two port network is similar to that for passive terminations which is expressed in S parameters. The various results derived in this paper are very useful for checking the stability of amplifiers, because both stability conditions and stability factors are simply calculated by using the S parameters without using the graphical method or transforming S parameters to Z, Y, H or G parameters. These stability conditions can be also used even if negative input or output resistance appears and even if the real part of source or load immittance is negative.},
keywords={},
doi={},
ISSN={},
month={March},}
Copy
TY - JOUR
TI - Stability of an Active Two Port Network in terms of S Parameters
T2 - IEICE TRANSACTIONS on Electronics
SP - 498
EP - 509
AU - Yoshihiro MIWA
PY - 1994
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E77-C
IS - 3
JA - IEICE TRANSACTIONS on Electronics
Y1 - March 1994
AB - The stability conditions and stability factors of terminated active two port networks are investigated. They are expressed with the S parameters of active devices and the radii and centers of the circles defined by source and load terminations. The stability conditions are applied to specific cases. Some of the results correspond to the stability conditions expressed in Z, Y, H or G parameters and one of the other stability conditions of terminated two port network is similar to that for passive terminations which is expressed in S parameters. The various results derived in this paper are very useful for checking the stability of amplifiers, because both stability conditions and stability factors are simply calculated by using the S parameters without using the graphical method or transforming S parameters to Z, Y, H or G parameters. These stability conditions can be also used even if negative input or output resistance appears and even if the real part of source or load immittance is negative.
ER -