This paper presents a design of a monolithic transformer using bond wires. The proposed transformer structure has several advantages such as high power handling and high efficiency. It shows that the measured insertion loss at the 1.9 GHz range is -1.54 dB (70%), which is higher than the spiral transformer of the same size. Also, it shows a phase error of less than 1 degree.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Eunil CHO, Sungho LEE, Jaejun LEE, Sangwook NAM, "A High-Efficient Transformer Using Bond Wires for Si RF IC" in IEICE TRANSACTIONS on Electronics,
vol. E93-C, no. 1, pp. 140-141, January 2010, doi: 10.1587/transele.E93.C.140.
Abstract: This paper presents a design of a monolithic transformer using bond wires. The proposed transformer structure has several advantages such as high power handling and high efficiency. It shows that the measured insertion loss at the 1.9 GHz range is -1.54 dB (70%), which is higher than the spiral transformer of the same size. Also, it shows a phase error of less than 1 degree.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.E93.C.140/_p
Copy
@ARTICLE{e93-c_1_140,
author={Eunil CHO, Sungho LEE, Jaejun LEE, Sangwook NAM, },
journal={IEICE TRANSACTIONS on Electronics},
title={A High-Efficient Transformer Using Bond Wires for Si RF IC},
year={2010},
volume={E93-C},
number={1},
pages={140-141},
abstract={This paper presents a design of a monolithic transformer using bond wires. The proposed transformer structure has several advantages such as high power handling and high efficiency. It shows that the measured insertion loss at the 1.9 GHz range is -1.54 dB (70%), which is higher than the spiral transformer of the same size. Also, it shows a phase error of less than 1 degree.},
keywords={},
doi={10.1587/transele.E93.C.140},
ISSN={1745-1353},
month={January},}
Copy
TY - JOUR
TI - A High-Efficient Transformer Using Bond Wires for Si RF IC
T2 - IEICE TRANSACTIONS on Electronics
SP - 140
EP - 141
AU - Eunil CHO
AU - Sungho LEE
AU - Jaejun LEE
AU - Sangwook NAM
PY - 2010
DO - 10.1587/transele.E93.C.140
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E93-C
IS - 1
JA - IEICE TRANSACTIONS on Electronics
Y1 - January 2010
AB - This paper presents a design of a monolithic transformer using bond wires. The proposed transformer structure has several advantages such as high power handling and high efficiency. It shows that the measured insertion loss at the 1.9 GHz range is -1.54 dB (70%), which is higher than the spiral transformer of the same size. Also, it shows a phase error of less than 1 degree.
ER -