Noncontact PIM Measurement Method Using Partial Impedance-Matching Method

Kensuke SAITO, Daijiro ISHIBASHI, Nobuhiro KUGA

  • Full Text Views

    0

  • Cite this

Summary :

In this letter, we propose a partial impedance-matching method using a two-strip resonator for noncontact Passive Intermodulation (PIM) measurements using a coaxial tube. It is shown that the strip closer to the inner tube of the coaxial tube is dominant in the observed PIM characteristics while both strips are excited equally. The ideal efficiency of power to each strip is 50%, which is a significant improvement in comparison with conventional methods.

Publication
IEICE TRANSACTIONS on Electronics Vol.E96-C No.9 pp.1151-1154
Publication Date
2013/09/01
Publicized
Online ISSN
1745-1353
DOI
10.1587/transele.E96.C.1151
Type of Manuscript
BRIEF PAPER
Category

Authors

Kensuke SAITO
  Yokohama National Univ.
Daijiro ISHIBASHI
  Yokohama National Univ.
Nobuhiro KUGA
  Yokohama National Univ.

Keyword