The search functionality is under construction.
The search functionality is under construction.

Keyword Search Result

[Keyword] coaxial line(10hit)

1-10hit
  • Monocone Antenna with Short Elements on Wideband Choke Structure Using Composite Right/Left-Handed Coaxial Line

    Kazuya MATSUBAYASHI  Naobumi MICHISHITA  Hisashi MORISHITA  

     
    PAPER-Antennas and Propagation

      Pubricized:
    2021/06/01
      Vol:
    E104-B No:11
      Page(s):
    1408-1418

    The composite right/left-handed (CRLH) coaxial line (CL) with wideband electromagnetic band gap (EBG) is applied to the wideband choke structure for a monocone antenna with short elements, and the resulting characteristics are considered. In the proposed antenna, impedance matching and leakage current suppression can be achieved across a wideband off. The lowest frequency (|S11| ≤ -10dB) of the proposed antenna is about the same as that of the monocone antenna on an infinite ground plane. In addition, the radiation patterns of the proposed antenna are close to the figure of eight in wideband. The proposed antenna is prototyped, and the validity of the simulation is verified through measurement.

  • Dielectric Measurement in Liquids Using an Estimation Equation without Short Termination via the Cut-Off Circular Waveguide Reflection Method

    Kouji SHIBATA  

     
    PAPER

      Vol:
    E101-C No:8
      Page(s):
    627-636

    In this study, a theory for estimating the dielectric properties for unknown materials from three reference materials without using a short condition was developed. Specifically, the relationships linking the S parameter, electrostatic capacity, the measurement instrument and the jig were determined for four equivalent circuits with three reference materials and an unknown material inserted into the jig. An equation for estimation of complex permittivity from three reference materials without short termination was thus derived. The formula's accuracy was then numerically verified for cases in which values indicating the dielectric properties of the reference materials and the actual material differed significantly, thereby verifying the effectiveness of the proposed method. Next, it was also found that dielectric constant could be correctly determined even when the observation plane was moved to the SOL calibration plane on the generator side. The dielectric properties of various liquids in the 0.50, 1.0 and 2.5 GHz bands as measured using the proposed method were then compared with corresponding conventional-method values. Finally, the validity of the proposed method was also indicated by measurement values showing the frequency characteristics of dielectric properties at frequencies ranging from 0.50 to 3.0 GHz.

  • Simplification of Liquid Dielectric Property Evaluation Based on Comparison with Reference Materials and Electromagnetic Analysis Using the Cut-Off Waveguide Reflection Method

    Kouji SHIBATA  Masaki KOBAYASHI  

     
    PAPER

      Vol:
    E100-C No:10
      Page(s):
    908-917

    In this study, expressions were compared with reference material using the coaxial feed-type open-ended cut-off circular waveguide reflection method to support simple and instantaneous evaluation of dielectric constants in small amounts of scarce liquids over a broad frequency range. S11 values were determined via electromagnetic analysis for individual jig structure conditions and dielectric property values without actual S11 measurement under the condition that the tip of the measurement jig with open and short-ended conditions and with the test material inserted. Next, information on the relationships linking jig structure, dielectric properties and S11 properties was stored on a database to simplify the procedure and improve accuracy in reference material evaluation. The accuracy of the estimation formula was first theoretically verified for cases in which values indicating the dielectric properties of the reference material and the actual material differed significantly to verify the effectiveness of the proposed method. The results indicated that dielectric property values for various liquids measured at 0.5 and 1.0GHz using the proposed method corresponded closely to those obtained using the method previously proposed by the authors. The effectiveness of the proposed method was evaluated by determining the dielectric properties of certain liquids at octave-range continuous frequencies between 0.5 and 1.0GHz based on interpolation from limited data of several frequencies. The results indicated that the approach enables quicker and easier measurement to establish the complex permittivity of liquids over a broad frequency range than the previous method.

  • A Novel Directional Coupler Loaded with Feedback Capacitances and Its Applications

    Motomi ABE  Yukihiro TAHARA  Tetsu OWADA  Naofumi YONEDA  Hiroaki MIYASHITA  

     
    PAPER-Microwaves, Millimeter-Waves

      Vol:
    E99-C No:1
      Page(s):
    85-94

    A novel directional coupler loaded with feedback capacitances on the coupled lines is presented. Its effect of enhancing the coupling is qualitatively shown by deriving an equation for the coupling. Besides, a method to compensate for the phase difference between the even and odd modes of the coupler is presented. To demonstrate, a novel tandem 3-dB coupler consisting of the proposed coupled lines is designed and described. In addition, a waveguide (rectangular coaxial line) 8×8 HYB matrix using planar double-layer structure that is composed of the proposed tandem 3-dB couplers and branch-line couplers, which is operated in S-band, is designed and fabricated showing excellent performance.

  • Noncontact PIM Measurement Method Using Partial Impedance-Matching Method

    Kensuke SAITO  Daijiro ISHIBASHI  Nobuhiro KUGA  

     
    BRIEF PAPER

      Vol:
    E96-C No:9
      Page(s):
    1151-1154

    In this letter, we propose a partial impedance-matching method using a two-strip resonator for noncontact Passive Intermodulation (PIM) measurements using a coaxial tube. It is shown that the strip closer to the inner tube of the coaxial tube is dominant in the observed PIM characteristics while both strips are excited equally. The ideal efficiency of power to each strip is 50%, which is a significant improvement in comparison with conventional methods.

  • Inclined Slot Array Antennas on a Hollow Rectangular Coaxial Line

    Satoshi YAMAGUCHI  Yukihiro TAHARA  Toru TAKAHASHI  Kazushi NISHIZAWA  Hiroaki MIYASHITA  Yoshihiko KONISHI  

     
    PAPER-Antennas and Propagation

      Vol:
    E95-B No:9
      Page(s):
    2870-2877

    Slotted-waveguide array antennas are attractive because of their low-loss characteristics at high frequencies. Several types of slotted arrays whose polarization angles are inclined to the waveguide axis have been reported. In this paper, we propose a new type of slot array antenna on a rectangular coaxial line for minimizing the waveguide width. As opposed to a conventional waveguide, there is no “cut-off” concept in our proposal because the coaxial line is a transverse electromagnetic (TEM) line. Therefore it is possible to guide the wave even if the diameter of the line is much smaller than that of the waveguide. Moreover, the proposed antenna is a resonant slot array antenna that is based on standing-wave excitation and is thus different from traveling-wave antennas (such as a leaky coaxial cable (LCX)).

  • Measurement of Complex Permittivity for Liquid Materials Using the Open-Ended Cut-Off Waveguide Reflection Method

    Kouji SHIBATA  

     
    PAPER-Microwaves, Millimeter-Waves

      Vol:
    E93-C No:11
      Page(s):
    1621-1629

    Various studies of specific absorption rates (SARs) using liquid phantoms imitating human body tissues have been widely carried out in electromagnetic compatibility (EMC) research fields. In order to establish accurate SARs for measurement, a faithful mockup of human body tissue is needed. Therefore, knowledge of the accurate measurement of sample materials with high permittivity and high loss is very important. In this study, the complex permittivity of tap water, ethanol, methanol and isopropanol is measured by the open-ended cut-off circular waveguide reflection method. The effectiveness of the method presented here of measuring a liquid phantom with high-permittivity and high-loss is also confirmed by comparing the measured results with the results obtained by the TM010 circular cavity resonator method. At this time, the effects on the input impedance under variations of the insertion length and termination conditions were studied. Then the complex permittivity of tap water, ethanol, methanol and isopropanol was measured at frequencies ranging from 0.5 to 3.0 GHz using the measurement procedure above. As a result, we confirmed the frequency characteristics of the complex permittivity for a wide variety of high-loss liquid materials.

  • Spectral Domain Approach to the Scattering Analysis of Coaxial Discontinuities

    Takamichi NAKATA  Hiroaki YOSHITAKE  Kikuo WAKINO  Yu-De LIN  Tohru TANI  Toshihide KITAZAWA  

     
    PAPER-Numerical Techniques, Computational Electromagnetic

      Vol:
    E90-C No:2
      Page(s):
    275-281

    The extended version of spectral domain approach (ESDA) is applied to evaluate the scattering characteristics of discontinuities in coaxial line. Discontinuities may be in inner and/or outer conductor of coaxial line. This method secures the high accuracy by considering the singularities of fields near the conductor edge properly. The computational labor of the new method is far lighter than that of FEM, so that novel method is suitable for the time consuming iterative computation such as fitting procedure in material evaluation or optimization of antenna design.

  • Method for Estimating Complex Permittivity Based on Measuring Effective Permittivity of Dielectric Mixtures in Radio Frequency Band

    Hidetoshi EBARA  Kensuke TANI  Teruo ONISHI  Shinji UEBAYASHI  Osamu HASHIMOTO  

     
    PAPER-Biological Effects

      Vol:
    E88-B No:8
      Page(s):
    3269-3274

    This paper proposes a method for estimating the complex permittivity of a small quantity of a sample such as a biological membrane. The feature of this method is that a material with an unknown complex permittivity is mixed with a material with a known complex permittivity in a number of volume ratios. The unknown complex permittivity is estimated by measuring the effective permittivity of the mixtures and by using the mixing formula, which is applied to the composite material. The validity of this estimation method is evaluated using a phospholipid, which is the primary constituent of a biological membrane, in the frequency range from 0.8 GHz to 6 GHz. We confirm that the measured effective permittivity of the phospholipid mixtures, which comprise the phospholipid and Ringer's solution in a number of volume ratios, corresponds to that of the Lichtenecker formula. Additionally, by preparing a number of samples with varying volume ratios the estimation error can be decreased. This estimation method is considered to be effective in the measurement of the complex permittivity for a biological membrane.

  • Measurement of Complex Permittivity for Liquid Phantom by Transmission Line Method Using Coaxial Line

    Kouji SHIBATA  Kensuke TANI  Osamu HASHIMOTO  Kouji WADA  

     
    PAPER-General Methods, Materials, and Passive Circuits

      Vol:
    E87-C No:5
      Page(s):
    689-693

    This paper is focused on the measurement of the complex permittivity of a liquid phantom by the transmission line method using a coaxial line for measuring high-permittivity and high-loss materials. First, the complex permittivity of the liquid phantom material is measured under various physical lengths of the coaxial line for accurate measurement. Secondly, comparison between the measured result and the result obtained by the coaxial probe method is carried out in the frequency range from 0.5 to 3 GHz. Finally, the measurement error included in the complex permittivity is estimated quantitatively. The discussions lead to the conclusion that accurate measurement of the liquid material with high-permittivity and high-loss is possible by the presented method.